Series:JC-SWA07-08 series
Type: JC-SWA07-08
Construction category: D
Operation method: Push button switch
Configuration: Single-Pole Single -Throw (SPST)
Terminal form: Solder Terminal
Protection: IP40
NO. |
quantity |
Items |
Material |
1 |
1 |
Core pin |
PA66 |
2 |
1 |
Sheet |
Phosphor bronze silver plated |
3 |
1 |
Cover |
Phosphor bronze |
4 | 1 |
Base |
LCP |
5 | 1 |
Contact |
Stainless steel silver plated |
6 | 1 |
Spring |
Stainless steel |
Note: Returned plastic should not exceed 20%.
Widely used in home appliance, electronic equipment, automatic machine, communication equipment, car electron, apparatus and instrument, electric motion tool etc.
Rice cooker
Slow cooker
Electric Heating Faucet
Shredder
Computer mouse
Electromagnetic lock
Baby chair
CNC machine tools
Power generator
Test equipment
Elevator
Power tools
Air conditioner
Water heater control panel
Bathroom products
Vacuum cleaner
Kitchen products
Gas valve
Range hood machine
Microwave oven
Pass-through machine
3.DETAIL SPECIFICATIONS:
Type:JC-SWA07-08
Construction category:D
Operation method:Push button switch
Configuration:Single-Pole Single -Throw (SPST)
Terminal form:Solder Terminal
Protection:IP40
Ratings 0.1A 12VDC
3.1 General
3.1.1Application This specification is applied to KAN-J4 Power Switch used for electronic equipment.
3.1.2 Operating temperature range -10℃ to +60℃
3.1.3 Test conditions Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows
Ambient temperature:15~35℃
Relative humidity:45~85%
Air pressure:86~106kPa (860~1060 mbar)
Should any doubt arise in judgment. tests shall be conducted at the following conditions.
Ambient temperature:20±2℃
Relative humidity:60~70%
Air pressure:86~106kPa (860~1060 mbar)
3.2Appearance construction and dimensions
3.2.1 Appearance Switch shall have good finishing, and no rust crack or plating failures.
3.2.2Construction and dimensions Refer to individual product drawing.
NO. |
Items |
Test conditions |
3.3.1 |
Contact resistance |
The contact resistance should be 50mΩ(Max). |
3.3.2 |
Insulation resistance |
It is measured with 500V DC 1minute should be 100MΩ(Min). |
3.3.3 |
Dielectric strength |
AC 1000V,1min.(before endurance test) AC 2000V,1min.(after endurance test) |
Item |
Description |
Test Conditions |
1 |
Operating Force |
500gf±50 |
2 |
Operating Life |
The mechanical life all of 50 000 cycles |
3 |
Contact Spacing |
Min. 3.0mm (IEC61058) |
3.5Durability
NO. |
Item |
Test condition |
Criteria |
3.5.1 |
Operation life |
Measurement shall be made following the test set forth below: DC 12V, 50 mA resistance load; Rate of operation: 60 times/min.; Operating Force:1.5OF; Average fault-free life: 50,000 cycles Test voltages shall be applied for 1 min |
Contact resistance: ≤200mΩ Contact bounce: ≤10ms Operating Force: initial value±30% |
4. DRAWING & DIMENSION
Copyright 2019 By Switech Electronics Co.,Ltd