Series:PS-12E05 series
This specification is applied to PS4-B202-60 Power Switch used for electronic equipment.
Operating temperature range: 0℃ to +85℃
Test conditions Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows
Ambient temperature: 15~35℃
Relative humidity: 45~85%
Air pressure: 86~106kPa (860~1060 mbar)
PARTS LIST:
NO. |
quantity |
Name |
Material |
1 |
1 |
Case |
T375J(UL94V—0) |
2 |
1 |
Handspike |
PBT/PET(UL94V—0) |
3 |
1 |
Cover |
Armor Plate, Nickel plated |
4 |
1 |
Spring holder |
1Cr18Ni9Ti |
5 |
1 |
Spring V |
QBe2 |
6 |
1 |
Fulcrum |
H62, Silver plated |
7 |
1 |
Contact arm |
H62, Silver plated |
8 |
1 |
Moving contact |
AgNi10/Cu |
9 |
1 |
Contact arm |
H62, Silver plated |
10 | 1 |
Terminal |
H62, Silver plated |
11 | 1 |
Fixed contact |
AgNi10/Cu |
12 | 1 |
Spring |
Beryllium alloy Qbe2 |
13 | 1 |
Releasing spring |
72A,Nickel plated |
Returned plastic should not exceed 20%.
Application
This specification is applied to PS-12E05 Power Switch used for electronic equipment.
Operating temperature range 0℃ to +85℃
Test conditions Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows
Ambient temperature 15~35℃
3 General
3.1.1 Application This specification is applied to PS-22E05 Power Switch used for electronic equipment.
3.1.2 Operating temperature range 0℃ to +85℃
3.1.3 Test conditions Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows
Ambient temperature:15~35℃
Relative humidity:45~85%
Air pressure:86~106kPa (860~1060 mbar)
Should any doubt arise in judgment. tests shall be conducted at the following conditions.
Ambient temperature:20±2℃
Relative humidity:60~70%
Air pressure:86~106kPa (860~1060 mbar)
3.2Appearance construction and dimensions
3.2.1 Appearance Switch shall have good finishing, and no rust crack or plating failures.
3.2.2Construction and dimensions Refer to individual product drawing.
Trip 2.5±0.5mm
Contact pressure ≥0.4N
The deviation in contact center no large than a quarter of contact diameter
Gap≥2.5mm
Drive type Press button kind, self-lock singe reset mechanical system
NO. |
Items |
Test conditions |
Criteria |
3.3.1 |
Contact resistance |
MEASURED AT 1 KHz SMALL CURRENT(100 mA OR LESS)
|
50mΩ MAX 50毫欧以下。 |
3.3.2 |
Insulation resistance |
APPLY A VOLTAGE OF 500V DC SHALL BE APPLIED FOR 1 MIN AFTER WHICH MEASUREMENT BE MADE: (1) BETWEEN TERMINAL. (2) BETWEEN INDIVIDUAL TERMINAL AND FRAME.
|
100MΩ MIN
|
3.3.3 |
Voltage proof |
AC 500V rms(50~60Hz) FOR 1 MIN TRIP CURRENT: 0.5 mA 1)BETWEEN TERMINAL. 2)BETWEEN INDIVIDUAL TERMINAL AND FRAME.
|
WITHOUT DAMAGE TO PARTS ARCING OR BREAKDOWN ETC.
|
Item |
Description |
Test Conditions |
Standards |
1 |
Terminal strength |
A STATIC LOAD OF 300 gf SHALL BE APPLIED TO THE TERMINAL FOR 15 SEC. IN ANY DIRECTION.
|
THERE SHALL BE NO DAMAGE TO THE TERMINAL SUCH AS CRACKS, LOOSENESS OR PLAY.ELECTRICAL AND MECHANICALCHARACTERISTICS SHALL BE SATISFIED. |
2 |
DISPLACEMENT OF ACTUATOR (KNOB)
|
A STATIC LOAD OF 10N(1Kgf)SHALL BE APPLIED TO THE TOP OF THE ACTUATOR(KNOB) AND THEN DISPLACEMENT SHALL BE MEASURED TO THE DIRECTION OF THE ARROW. |
THE LEVER SHALL HAVE NO ANFUNCTION IS NORMALLY.
|
3 |
LIFE TEST
|
WITHOUT LOAD: AN ACTUATOR SHALL BE SUBJECT TO 10,000 CYCLES AT A SPEED OF 15~18 CYCLES FOR 1 MIN.
|
1)CONTACT RESISTANCE 100 mΩ MAX 2)INSULATION RESISTANCE 50MΩ MIN. 3)WITHSTAND VOLTAGE AC 500V, 1 MINUTE. (4)OPERATING FORCE ±30% INITIAL VALUE. (5)WITHOUT DAMAGE TO PARTS ARCING OR BREAKDOWN ETC.
|
NO. |
Item |
Test conditions |
Criteria |
3.5.1 |
HUMIDITY
|
THE JACK SHALL BE STORED AT A TEMPERATURE OF 40±2 °C AND A HUMIDITY OF 90% TO 95% FOR 96 Hr . THEN THE JACK SHALL BE MAINTAINED AT STANDARD ATMOSPHERIC CONDITION FOR 1 Hr FOR OTHER PROCEDURES.
|
|
3.5.2 |
STANDARD ATMOSPHERIC CONDITIONS
|
UNLESS OTHERWISE SPECIFIED. THE STANDARD RANGE OF ATMOSPHERIC CONDITIONS FOR MAKING MEASUREMENTS AND TESTS ARE AS FOLLOWS: (1) AMBIENT TEMPERATURE : 5 °C TO 35 °C (2) RELATIVE HUMIDITY: 45% TO 85% (3) AIR PRESSURE 86Kpa TO 106Kpa
|
|
3.5.3 |
PRACTICAL TEMPERATURE RANG
|
-16 °C ~ +60°C
|
|
3.5.4 |
STORAGE METHOD
|
(1) IF DON'T USE THE PRODUCT IMMEDIATELY,STORE IT AS DELIVERED IN THE FOLLOWING ENVIRONMENT: WITH NEITHER DIRECT SUNSHINE NOR CORROSIVE GAS AND IN NORMAL TEMPERATURES. HOWEVER, IT IS RECOMMENDED THAT YOU SHOULD USE IT AS SOON AS POSSIBLE BEFORE SIX MONTHS PASS. |
|
(2) AFTER BREAK THE SEAL,IT SHOULD PUT THE REMAINING IN A PLASTIC BAG TO SEPARATE IT FROM THE OUTSIDE AND STORE IN THE SAME ENVIRONMENT MENTIONED ABOVE. YOU SHOULD USE IT UP AS SOON AS POSSIBLE. |
|||
(3) DO NOT STACK TOO MANY SWITCHES FOR STRAFE.
|
3.6.1 |
Solder ability |
THE TOP OF THE TERMINALS SHALL BE DIPPED 2mm IN THE SOLDER BATH OF 235±5 °C FOR 3±0.5 SECONDS.
|
The area of dip tin should capture the 75% impregnated area |
|||||||||
3.6.2 |
Resistance to soldering heat |
The switch will be inspect under such conditions below Temperature and impregnated time
(2) TMMERSION DEPTH: IMMERSION DEPTH UP TO THE SURFACE OF THE BOARD THICKNESS OF PRINTED WIRING BOARD 1.6 mm.
|
WITHOUT DEFORMATION OF CASE OR EXCESSIVE LOOSENESS OFTERMINALS MECHANICAL AND ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED.
|
|||||||||
3.6.3 |
HEAT TEST
|
THE JACK SHALL BE STORED AT A TEMPERATURE OF 85±2 °C FOR 96 HOURS AND THEN IT SHALL BE SUBJECTED TO THE CONTROLLED RECOVERY CONDITIONS FOR 1 HOUR AFTER WHICH MEASUREMENT SHALL BE MADE.
|
||||||||||
3.6.4 |
COLD TEST
|
THE JACK SHALL BE STORED AT A TEMPERATURE OF -10±2 °C FOR 96 HOURS AND THEN IT SHALL BE SUBJECTED TO THE CONTROLLED RECOVERY CONDITIONS FOR 1 HOUR AFTER WHICH MEASUREMENT SHALL BE MADE.
|
4. DRAWING & DIMENSION:
Copyright 2019 By Switech Electronics Co.,Ltd