Series:PB12 series
Type: LA160-12AYSW-11
Construction category: D
Operation method: Push button switch
Configuration: Single-Pole Double -Throw (SPDT)
Terminal form: Solder Terminal
Protection: IP40
Approved Rating |
Mark |
Reference No. |
|
UL&CUL |
|
|
VDE |
|
0.7A 110VAC; 0.5A 220VAC; 0.1A 220VDC |
CQC |
2011010305454397 |
Enormous remote
controller and portable remote controller
Instrumentation
Medical equipment
Telecommunications and networking equipment
Computers & peripherals
Instrumentation and controls
Industrial electronic equipment
Industrial remote controller
Medical Equipment
Communication
Outdoor Controls
Public building, Home security, Business building, Industrial equipment…etc.
3.DETAIL SPECIFICATIONS:
Type:LA160-12AYSW-11
Construction category:D
Operation method:Push button switch
Configuration:Single-Pole Double -Throw (SPDT)
Terminal form:Solder Terminal
Protection:IP40
Ratings: 0.7A 110VAC; 0.5A 220VAC; 0.1A 220VDC
Withstand voltage: 1000VAC,1Min
3.1 General
3.1.1Application This specification is applied to LA160 Push button Switch used for electronic equipment.
3.1.2 Operating temperature range -20℃ to +55℃
3.1.3 Test conditions Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows
Ambient temperature:15~35℃
Relative humidity:45~85%
Air pressure:86~106kPa (860~1060 mbar)
Should any doubt arise in judgment. tests shall be conducted at the following conditions.
Ambient temperature:20±2℃
Relative humidity:60~70%
Air pressure:86~106kPa (860~1060 mbar)
3.2Appearance construction and dimensions
3.2.1 Appearance Switch shall have good finishing, and no rust crack or plating failures.
3.2.2Construction and dimensions Refer to individual product drawing.
NO. |
Items |
Test conditions |
3.3.1 |
Contact resistance |
The contact resistance should be 50mΩ(Max). |
3.3.2 |
Insulation resistance |
It is measured with 500V DC 1minute should be 100MΩ(Min). |
3.3.3 |
Dielectric strength |
AC 2000V,1min.(before endurance test) AC 1500V,1min.(after endurance test) |
Item |
Description |
Test Conditions |
1 |
Operating Force |
300gf±100 |
2 |
Operating Life |
The mechanical life all of 1000 000 cycles |
3 |
Contact Spacing |
Min. 3.0mm (IEC61058) |
3.5Durability
NO. |
Item |
Test condition |
Criteria |
||||||||||||||||||
3.5.1 |
Endurance (According to UL61058) |
0.7A 110VAC; 0.5A 220VAC; 0.1A 220VDC Switch shall be operated according to following sequence (Test1~Test2)
Voltage proof(Cut-off current:0.5mA) 0.7A 110VAC; 0.5A 220VAC; 0.1A 220VDC Switch shall be operated 100,000 cycles at 15-20 cycles/min. Test voltages shall be applied for 1 min |
Insulation resistance(item 4.2): 50MΩ MIN Voltage proof: Terminal and ground:1000VAC No dielectric breakdown shall occur. Operating characteristic (item 5.1): Operating characteristic variety Within ±20% of specifiedvalue . 6000 cycles temperature rise:45℃MAX; 10,000 cycles temperature rise:55℃ MAX;
No abnormalities shall be recognized in appearance and construction |
||||||||||||||||||
3.5.2 |
Endurance (According to EN61058-1 /IEC61058-1) |
0.7A 110VAC; 0.5A 220VAC; 0.1A 220VDC Switch shall be operated 100,000 cycles at 15~20 cycles/min Voltage proof(Cut-off current:0.5mA) Test voltages shall be applied for 1 min. |
Insulation resistance(item 4.2): 50MΩ MIN Voltage proof: Terminal and terminal:750VAC Terminal and ground:1500VAC No dielectric breakdown shall occur. Operating characteristic (item 5.1): Operating characteristic variety Within ±20% of specifiedvalue . Temperature rise:55℃ MAX No abnormalities shall be recognized in appearance and construction |
3.6. SOLDERING
Solder ability and Resistance to sold heat according to IEC 68-2-20
4. DRAWING & DIMENSION:
5.1 |
Packing material: |
Plastic box / |
5.2 |
Packing number: |
100 pieces per bag |
5.3 |
Weight: |
Gross Weight: kg Net Weight: kg |
5.4 |
Size: |
57.0 x 26.0 x 32.0 CM / 0.045CBM |
Copyright 2019 By Switech Electronics Co.,Ltd