DC022A DC socket, convenienve receptacle, appliance outlet
Series:DC022A
Quick Detail:
Type: DC022A
Rating: DC30V 2.0A
- Remarks
- Applications
- Technical parameters
Remarks
PACKING:
4.1 |
Packing material: |
Plastic bag |
4.2 |
Packing number: |
500 pieces per bag 1 shipping carton 7500 pieces |
4.3 |
Weight: |
Gross Weight: 26 kg Net Weight: 24.5 kg |
4.4 |
Size: |
57*27*32CM /0.049248CBM |
Applications
Home / Household Appliances
Electric kettle, Robot cleaner, Dust catcher, Vacuum cleaner, Coffee maker, Running machine etc.
Electronic Equipment
Toys, Power tools, Car control panel etc.
Medical Equipment
Communication Equipment
Automation Equipment
Automotive Electronics
Instrumentation
Technical parameters
-
Type: DC022A
Rating: DC30V 2.0A
1.APPEARANCE, STRUCTURE AND DIMENSION
1.1 APPEARANCE Have no remarkable damage ,crack and rust etc
1.2 CONSTRUCTION DIMENSION Apply to the appended drawing
2. ELECTRONICAL CHARACTERISTICS:
NO.
Items
Test conditions
Criteria
2.1
CONTACT RESISTANCE
Being measured at 1KHz small current contact resistance meter.
30mΩ MAX
2.2
INSULATION RESISTANCE
Measurements shall be made following application of DC500V potential across terminals and across terminals and frame for 1 minute.
100MΩ MIN
2.3
WITHSTAND VOLTAGE
AC 500V (50Hz or 60Hz) shall be applied across terminals and across terminals and frame for one minute
There shall be no breakdown.
3. DURABILITY:
NO.
Items
Test conditions
Criteria
3.1
SOLDERI NG TEST.
The tip of the terminals shall be dipped 2mm in the solder bath at a temperature of 230± 5℃ for 3±0.5sec
A new uniform coating of solder shall cover a minimum of 90 of the surface being immersed
3.2
LIFE TEST.
5,000 cycles of operation at a rate of 20-30cycles per minute with unloading.
(1). Contact resistance . 40mΩmax
(2). Insertion and withdraw force 30initial value
(3). ITEM 專案-4B
(4). ITEM 專案-4C
(5). ITEM 專案-5B
3.3
HEAT TEST.
85 ± 2 ℃ for 48 hours after test keep in normal condition for 30 minutes在85±2℃
(1). Contact resistance 50mΩ max.
(2). Insulation resistance. 50MΩ
(3). There shall be no sign of damage mechanically and electrically.
3.4
HUMIDITY TEST.
89% RH for 48 hrs. after test keep in normal condition for 30 min
3.5
COLD TEST.
At –40 ± 2 ℃ for 48 hrs. after test keep in normal condition for 30 min.
4. MECHANICAL CHARACTERISTICS:
NO.
Items
Test conditions
Criteria
4.1
INSERTION ANDWITHDRAWFORCE
Being measure at across spring piece and across matching plug for ergometer
Insertion and extraction force5-18N
4.2
TERMINAL STRENGTH
A static force of 500gf being applied in one direction on the tip of terminal for 1 minute.
There shall be no sign of damage mechanically and electrically.
5.DRAWING & DIMENSION: