+ 86-0512-62885849

EN
todas las categorias

Inicio /Productos /Empuje el interruptor de botón /Interruptor de botón general

PS-12E15 interruptor de botón momentáneo de un polo con clavijas 3

serie:PS-12E05 series

Detalle rápido:

This specification is applied to PS-22E15 Power Switch used for electronic equipment.
Operating temperature range: -10℃ to +85℃
Test conditions Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows
Temperatura ambiente: 15 ~ 35 ℃
Humedad relativa: 45 ~ 85%
Air pressure: 86~106kPa (860~1060 mbar)

observaciones

APROBACIÓN Y CALIFICACIÓN DE SEGURIDAD:

Calificación aprobada

Marco

Numero de referencia.

TV8/120VAC TV-8 125VAC 10T85 10GPA 125/250VAC 10A 125/250VAC

1E4 10T85

UL y CUL

E176213

4A/128A 250VAC 10T85 1E4

VDE

129571

8A/128A 250VAC 1E4

CQC

CQC02002002689

4A/128A 250VAC 10T85 1E4

NEMKO

P10213186

4A/128A 250VAC 10T85 1E4

SEMKO

1021831

4A/128A 250VAC 10T85 1E4

FIMKO

261487

4A/128A 250VAC 10T85 1E4

DEMKO

314333-02 D-03541

4A/128A 250VAC 10T85 1E4

CE

SH10041366-V1

TUV

10A 125/250VAC 1E4 10T85

ENEC

ENEC-00946

4/128A 250VAC 10T85 1E4

EK

SU0230-7006A

10A 125/250VAC 1E4 10T85

CB

SE-51323 DK-40111-UL

LISTA DE PARTES:

NO.

la cantidad

Nombre

Material

1

1

KONB

POM

2

1

BLOQUE

TIRA DE ACERO

3

1

SPRING

SUS

4

1

CAM STICK

PBS WIRE

5

1

SPRING PLATE

TIRA DE PBS

6

1

FRAME

TIRA DE ACERO

7

1

BASE

RESINA FENOLICA

8

1

TERMINAL

TIRA DE LATON

9

1

CONTACTO

PBS C5210R-EH

El plástico devuelto no debe exceder el 20%.

Aplicaciones

This specification is applied to PS-12E05 Power Switch used for electronic equipment.
Operating temperature range -10℃ to +85℃

Test conditions Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows
Temperatura ambiente 15 ~ 35 ℃

Parámetros técnicos

3 General
3.1.1 Application This specification is applied to PS-22E05 Power Switch used for electronic equipment.
3.1.2 Operating temperature range -10℃ to +85℃
Condiciones de prueba de 3.1.3 A menos que se especifique lo contrario. Las condiciones atmosféricas para realizar mediciones y pruebas son las siguientes
Temperatura ambiente: 15 ~ 35 ℃
Humedad relativa: 45 ~ 85%
Presión de aire: 86 ~ 106kPa (860 ~ 1060 mbar)
Si surge alguna duda en el juicio. Las pruebas se realizarán en las siguientes condiciones.
Temperatura ambiente: 20 ± 2 ℃
Humedad relativa: 60 ~ 70%
Presión de aire: 86 ~ 106kPa (860 ~ 1060 mbar)
3.2 Apariencia construcción y dimensiones
El interruptor de apariencia 3.2.1 debe tener un buen acabado y no presenta grietas de óxido ni fallas en el revestimiento.
3.2.2 Construcción y dimensiones Consulte el dibujo individual del producto.
Trip 2.5±0.5mm
Contact pressure ≥0.4N
The deviation in contact center no large than a quarter of contact diameter
Gap≥2.5mm
Drive type Press button kind, self-lock singe reset mechanical system


3.3. Electrical specifications

NO.

artículos

Condiciónes de la prueba

Criterios

3.3.1

Resistencia de contacto

MEASURED AT 1 KHz SMALL CURRENT(100 mA OR LESS)

30mΩ MAX

30毫欧以下。

3.3.2

Resistencia de aislamiento

APPLY A VOLTAGE OF 500V DC SHALL BE APPLIED FOR 1 MIN AFTER WHICH MEASUREMENT BE MADE:

(1) BETWEEN TERMINAL.

(2) BETWEEN INDIVIDUAL TERMINAL AND FRAME.

100MΩ MIN

3.3.3

Prueba de voltaje

AC 500V rms(50~60Hz) FOR 1 MIN TRIP CURRENT: 0.5 mA

1)BETWEEN TERMINAL.

2)BETWEEN INDIVIDUAL TERMINAL AND FRAME.

WITHOUT DAMAGE TO

PARTS ARCING OR BREAKDOWN ETC.

3.4 Mechanical characteristic

Asunto

Descripción

Condiciónes de la prueba

Estándares

1

Terminal strength

A STATIC LOAD OF 300 gf SHALL BE APPLIED TO THE TERMINAL FOR 15 SEC. IN ANY DIRECTION.

THERE SHALL BE NO DAMAGE TO THE TERMINAL SUCH AS

CRACKS, LOOSENESS OR PLAY.ELECTRICAL AND MECHANICALCHARACTERISTICS SHALL BE SATISFIED.

2

DISPLACEMENT OF ACTUATOR

(KNOB)

A STATIC LOAD OF 10N(1Kgf)SHALL BE APPLIED TO THE TOP OF

THE ACTUATOR(KNOB) AND THEN DISPLACEMENT SHALL BE

MEASURED TO THE DIRECTION OF THE ARROW.

THE LEVER SHALL HAVE NO ANFUNCTION IS NORMALLY.

3

LIFE TEST

WITHOUT LOAD: AN ACTUATOR SHALL BE SUBJECT TO 10,000 CYCLES AT A SPEED OF

15~18 CYCLES FOR 1 MIN.

1)CONTACT RESISTANCE 100 mΩ MAX

2)INSULATION RESISTANCE

50MΩ MIN.

3)WITHSTAND VOLTAGE

AC 500V, 1 MINUTE.

(4)OPERATING FORCE

±30% INITIAL VALUE.

(5)WITHOUT DAMAGE TO

PARTS ARCING OR BREAKDOWN ETC.

3.5. Durabilidad

NO.

Asunto

Condiciónes de la prueba

Criterios

3.5.1

HUMEDAD

THE JACK SHALL BE STORED AT A TEMPERATURE OF 40±2 °C AND A

HUMIDITY OF 90% TO 95% FOR 96 Hr . THEN THE JACK SHALL BE

MAINTAINED AT STANDARD ATMOSPHERIC CONDITION FOR 1 Hr FOR

OTHER PROCEDURES.

3.5.2

ESTANDAR

ATMOSPHERIC

CONDICIONES

UNLESS OTHERWISE SPECIFIED. THE STANDARD RANGE OF ATMOSPHERIC CONDITIONS FOR MAKING

MEASUREMENTS AND TESTS ARE AS FOLLOWS:

(1) AMBIENT TEMPERATURE : 5 °C TO 35 °C

(2) RELATIVE HUMIDITY: 45% TO 85%

(3) AIR PRESSURE 86Kpa TO 106Kpa

3.5.3

PRÁCTICO

TEMPERATURA

GRADO

-16 °C ~ +60°C

3.5.4

STORAGE METHOD

(1) IF DON'T USE THE PRODUCT IMMEDIATELY,STORE IT AS DELIVERED IN

THE FOLLOWING ENVIRONMENT: WITH NEITHER DIRECT SUNSHINE NOR

CORROSIVE GAS AND IN NORMAL TEMPERATURES. HOWEVER, IT IS

RECOMMENDED THAT YOU SHOULD USE IT AS SOON AS POSSIBLE BEFORE

SIX MONTHS PASS.

(2) AFTER BREAK THE SEAL,IT SHOULD PUT THE REMAINING IN A

PLASTIC BAG TO SEPARATE IT FROM THE OUTSIDE AND STORE IN THE

SAME ENVIRONMENT MENTIONED ABOVE. YOU SHOULD USE IT UP AS

SOON AS POSSIBLE.

(3) DO NOT STACK TOO MANY SWITCHES FOR STRAFE.

3.6 Rendimiento de soldadura

3.6.1

Capacidad de soldadura

THE TOP OF THE TERMINALS SHALL BE DIPPED 2mm IN THE SOLDER

BATH OF 230±5 °C FOR 3±0.5 SECONDS.

The area of dip tin should capture the 75% impregnated area

3.6.2

Resistencia al calor de soldadura

The switch will be inspect under such conditions below

Temperatura y tiempo impregnado.

Trial measure

temperatura (℃)

Veces)

Slot welding method

260 5 ±

3 1 ±

Soldering method

360 5 ±

3 1 ±

(2) TMMERSION DEPTH:

IMMERSION DEPTH UP TO THE SURFACE OF THE BOARD THICKNESS OF

PRINTED WIRING BOARD 1.6 mm.

WITHOUT DEFORMATION OF CASE OR EXCESSIVE

LOOSENESS OFTERMINALS

MECHANICAL AND ELECTRICAL

CHARACTERISTICS SHALL BE SATISFIED.

3.6.3

HEAT TEST

THE JACK SHALL BE STORED AT A TEMPERATURE OF 70±2 °C FOR 48 HOURS AND THEN IT SHALL BE SUBJECTED TO THE CONTROLLED RECOVERY CONDITIONS FOR 1 HOUR AFTER WHICH MEASUREMENT SHALL BE MADE.

3.6.4

COLD TEST

THE JACK SHALL BE STORED AT A TEMPERATURE OF -25±3 °C FOR 48 HOURS AND THEN IT SHALL BE SUBJECTED TO THE CONTROLLED RECOVERY CONDITIONS FOR 1 HOUR AFTER WHICH MEASUREMENT SHALL BE MADE.


4 DIBUJO Y DIMENSIÓN:



5 DIAGRAMA DE CIRCUITO: