serie:PS-12E05 series
This specification is applied to PS-22E15 Power Switch used for electronic equipment.
Operating temperature range: -10℃ to +85℃
Test conditions Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows
Temperatura ambiente: 15 ~ 35 ℃
Humedad relativa: 45 ~ 85%
Air pressure: 86~106kPa (860~1060 mbar)
Calificación aprobada |
Marco |
Numero de referencia. |
TV8/120VAC TV-8 125VAC 10T85 10GPA 125/250VAC 10A 125/250VAC 1E4 10T85 |
UL y CUL |
E176213 |
4A/128A 250VAC 10T85 1E4 |
VDE |
129571 |
8A/128A 250VAC 1E4 |
CQC |
CQC02002002689 |
4A/128A 250VAC 10T85 1E4 |
NEMKO |
P10213186 |
4A/128A 250VAC 10T85 1E4 |
SEMKO |
1021831 |
4A/128A 250VAC 10T85 1E4 |
FIMKO |
261487 |
4A/128A 250VAC 10T85 1E4 |
DEMKO |
314333-02 D-03541 |
4A/128A 250VAC 10T85 1E4 |
CE |
SH10041366-V1 |
|
TUV |
|
10A 125/250VAC 1E4 10T85 |
ENEC |
ENEC-00946 |
4/128A 250VAC 10T85 1E4 |
EK |
SU0230-7006A |
10A 125/250VAC 1E4 10T85 |
CB |
SE-51323 DK-40111-UL |
LISTA DE PARTES:
NO. |
la cantidad |
Nombre |
Material |
1 |
1 |
KONB |
POM |
2 |
1 |
BLOQUE |
TIRA DE ACERO |
3 |
1 |
SPRING |
SUS |
4 |
1 |
CAM STICK |
PBS WIRE |
5 |
1 |
SPRING PLATE |
TIRA DE PBS |
6 |
1 |
FRAME |
TIRA DE ACERO |
7 |
1 |
BASE |
RESINA FENOLICA |
8 |
1 |
TERMINAL |
TIRA DE LATON |
9 |
1 |
CONTACTO |
PBS C5210R-EH |
El plástico devuelto no debe exceder el 20%.
This specification is applied to PS-12E05 Power Switch used for electronic equipment.
Operating temperature range -10℃ to +85℃
Test conditions Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows
Temperatura ambiente 15 ~ 35 ℃
3 General
3.1.1 Application This specification is applied to PS-22E05 Power Switch used for electronic equipment.
3.1.2 Operating temperature range -10℃ to +85℃
Condiciones de prueba de 3.1.3 A menos que se especifique lo contrario. Las condiciones atmosféricas para realizar mediciones y pruebas son las siguientes
Temperatura ambiente: 15 ~ 35 ℃
Humedad relativa: 45 ~ 85%
Presión de aire: 86 ~ 106kPa (860 ~ 1060 mbar)
Si surge alguna duda en el juicio. Las pruebas se realizarán en las siguientes condiciones.
Temperatura ambiente: 20 ± 2 ℃
Humedad relativa: 60 ~ 70%
Presión de aire: 86 ~ 106kPa (860 ~ 1060 mbar)
3.2 Apariencia construcción y dimensiones
El interruptor de apariencia 3.2.1 debe tener un buen acabado y no presenta grietas de óxido ni fallas en el revestimiento.
3.2.2 Construcción y dimensiones Consulte el dibujo individual del producto.
Trip 2.5±0.5mm
Contact pressure ≥0.4N
The deviation in contact center no large than a quarter of contact diameter
Gap≥2.5mm
Drive type Press button kind, self-lock singe reset mechanical system
NO. |
artículos |
Condiciónes de la prueba |
Criterios |
3.3.1 |
Resistencia de contacto |
MEASURED AT 1 KHz SMALL CURRENT(100 mA OR LESS)
|
30mΩ MAX 30毫欧以下。 |
3.3.2 |
Resistencia de aislamiento |
APPLY A VOLTAGE OF 500V DC SHALL BE APPLIED FOR 1 MIN AFTER WHICH MEASUREMENT BE MADE: (1) BETWEEN TERMINAL. (2) BETWEEN INDIVIDUAL TERMINAL AND FRAME.
|
100MΩ MIN
|
3.3.3 |
Prueba de voltaje |
AC 500V rms(50~60Hz) FOR 1 MIN TRIP CURRENT: 0.5 mA 1)BETWEEN TERMINAL. 2)BETWEEN INDIVIDUAL TERMINAL AND FRAME.
|
WITHOUT DAMAGE TO PARTS ARCING OR BREAKDOWN ETC.
|
Asunto |
Descripción |
Condiciónes de la prueba |
Estándares |
1 |
Terminal strength |
A STATIC LOAD OF 300 gf SHALL BE APPLIED TO THE TERMINAL FOR 15 SEC. IN ANY DIRECTION.
|
THERE SHALL BE NO DAMAGE TO THE TERMINAL SUCH AS CRACKS, LOOSENESS OR PLAY.ELECTRICAL AND MECHANICALCHARACTERISTICS SHALL BE SATISFIED. |
2 |
DISPLACEMENT OF ACTUATOR (KNOB)
|
A STATIC LOAD OF 10N(1Kgf)SHALL BE APPLIED TO THE TOP OF THE ACTUATOR(KNOB) AND THEN DISPLACEMENT SHALL BE MEASURED TO THE DIRECTION OF THE ARROW. |
THE LEVER SHALL HAVE NO ANFUNCTION IS NORMALLY.
|
3 |
LIFE TEST
|
WITHOUT LOAD: AN ACTUATOR SHALL BE SUBJECT TO 10,000 CYCLES AT A SPEED OF 15~18 CYCLES FOR 1 MIN.
|
1)CONTACT RESISTANCE 100 mΩ MAX 2)INSULATION RESISTANCE 50MΩ MIN. 3)WITHSTAND VOLTAGE AC 500V, 1 MINUTE. (4)OPERATING FORCE ±30% INITIAL VALUE. (5)WITHOUT DAMAGE TO PARTS ARCING OR BREAKDOWN ETC.
|
NO. |
Asunto |
Condiciónes de la prueba |
Criterios |
3.5.1 |
HUMEDAD
|
THE JACK SHALL BE STORED AT A TEMPERATURE OF 40±2 °C AND A HUMIDITY OF 90% TO 95% FOR 96 Hr . THEN THE JACK SHALL BE MAINTAINED AT STANDARD ATMOSPHERIC CONDITION FOR 1 Hr FOR OTHER PROCEDURES.
|
|
3.5.2 |
ESTANDAR ATMOSPHERIC CONDICIONES
|
UNLESS OTHERWISE SPECIFIED. THE STANDARD RANGE OF ATMOSPHERIC CONDITIONS FOR MAKING MEASUREMENTS AND TESTS ARE AS FOLLOWS: (1) AMBIENT TEMPERATURE : 5 °C TO 35 °C (2) RELATIVE HUMIDITY: 45% TO 85% (3) AIR PRESSURE 86Kpa TO 106Kpa
|
|
3.5.3 |
PRÁCTICO TEMPERATURA GRADO
|
-16 °C ~ +60°C
|
|
3.5.4 |
STORAGE METHOD
|
(1) IF DON'T USE THE PRODUCT IMMEDIATELY,STORE IT AS DELIVERED IN THE FOLLOWING ENVIRONMENT: WITH NEITHER DIRECT SUNSHINE NOR CORROSIVE GAS AND IN NORMAL TEMPERATURES. HOWEVER, IT IS RECOMMENDED THAT YOU SHOULD USE IT AS SOON AS POSSIBLE BEFORE SIX MONTHS PASS. |
|
(2) AFTER BREAK THE SEAL,IT SHOULD PUT THE REMAINING IN A PLASTIC BAG TO SEPARATE IT FROM THE OUTSIDE AND STORE IN THE SAME ENVIRONMENT MENTIONED ABOVE. YOU SHOULD USE IT UP AS SOON AS POSSIBLE. |
|||
(3) DO NOT STACK TOO MANY SWITCHES FOR STRAFE.
|
3.6.1 |
Capacidad de soldadura |
THE TOP OF THE TERMINALS SHALL BE DIPPED 2mm IN THE SOLDER BATH OF 230±5 °C FOR 3±0.5 SECONDS.
|
The area of dip tin should capture the 75% impregnated area |
|||||||||
3.6.2 |
Resistencia al calor de soldadura |
The switch will be inspect under such conditions below Temperatura y tiempo impregnado.
(2) TMMERSION DEPTH: IMMERSION DEPTH UP TO THE SURFACE OF THE BOARD THICKNESS OF PRINTED WIRING BOARD 1.6 mm.
|
WITHOUT DEFORMATION OF CASE OR EXCESSIVE LOOSENESS OFTERMINALS MECHANICAL AND ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED.
|
|||||||||
3.6.3 |
HEAT TEST
|
THE JACK SHALL BE STORED AT A TEMPERATURE OF 70±2 °C FOR 48 HOURS AND THEN IT SHALL BE SUBJECTED TO THE CONTROLLED RECOVERY CONDITIONS FOR 1 HOUR AFTER WHICH MEASUREMENT SHALL BE MADE.
|
||||||||||
3.6.4 |
COLD TEST
|
THE JACK SHALL BE STORED AT A TEMPERATURE OF -25±3 °C FOR 48 HOURS AND THEN IT SHALL BE SUBJECTED TO THE CONTROLLED RECOVERY CONDITIONS FOR 1 HOUR AFTER WHICH MEASUREMENT SHALL BE MADE.
|
4 DIBUJO Y DIMENSIÓN:
5 DIAGRAMA DE CIRCUITO:
Copyright 2019 por Switech Electronics Co., Ltd