KAN-B2-25PSW28B high quality on-off 3pins SPDT round red illuminated rocker switch
Series:KAN-B2
Quick Detail:
Type: KAN-B2-25PSW28B
Construction category: D
Operation method: Rocker Action
Configuration: Single-Pole Single-Through (SPDT)
Terminal form: #187 quick-connect Terminal
Mounting: Snap-In
Protection: IP40
- Remarks
- Applications
- Technical parameters
Remarks
SAFETY APPROVAL & RATING:
Approved Rating |
Mark |
Reference No. |
12A24VDC 6.5A250VAC 13A125VAC |
UL&CUL |
E215677 |
|
VDE |
|
10(8)A250VAC T105/55 |
CQC |
CQC06002017321 |
|
NEMKO |
|
|
SEMKO |
|
|
FIMKO |
|
|
DEMKO |
|
CE |
|
|
10(8)A250VAC T105/55 |
TUV |
15013611 004 |
|
ENEC |
|
10(8)A250VAC T105/55 |
EK |
SU02027-12001 |
|
CB |
|
PARTS LIST:
ITEM |
NAME |
MATERIAL |
1 |
HOUSE |
NYLON |
2 |
SHAFT |
NYLON |
3 |
BUTTON |
NYLON |
4 |
SOLDERING TERMINAL |
BRASS STRIP |
5 |
MOVING TERMINAL |
BRONZE STRIP |
6 |
SUPPORT |
COPPER STRIP |
7 |
COMPRESSED SPRING |
STAINLESS STEEL WIRE |
8 |
TOP COLUMN |
BRASS STRIP |
9 |
CONTACT |
AgCdO / COPPER |
10 |
LED |
LED |
Applications
Home / Household Appliances
Electric kettle, Robot cleaner, Dust catcher, Vacuum cleaner, Coffee maker, Running machine etc.
Electronic Equipment
Toys, Power tools, Car control panel etc.
Technical parameters
1、 DETAIL SPECIFICATIONS:
Type: KAN-B2-25PSW28B
Construction category: D
Operation method: Rocker Action
Configuration: Single-Pole Single-Through (SPDT)
Terminal form: #187 quick-connect Terminal
Mounting: Snap-In
Protection: IP40
1.1 OPERATING CHARACTERISTICSNote:
Characteristics |
Units |
Standards |
Note |
Actuating Force |
N |
4±1.5 Max |
Original 4±1.5 . |
Contact Force |
N |
0.4 Min |
Original 0.4 Min |
Electrical Clearance |
mm |
3 Min |
Original 3 Min |
Actuating Force:The force required to move the actuator from the free to the operation position
1.2 GENERAL CHARACTERISTICS
1.2.1Application This specification is applied to KAN Rocker Switch used for electronic equipment.
1.2.2Operating temperature range -25℃ to +105℃
1.2.3Test conditions Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows
Ambient temperature: 15~35℃
Relative humidity: 45~85%
Air pressure: 86~106kPa (860~1060 mbar)
Should any doubt arise in judgment. tests shall be conducted at the following conditions.
Ambient temperature: 20±2℃
Relative humidity: 60~70%
Air pressure: 86~106kPa (860~1060 mbar)
1.3 Appearance construction and dimensions
1.3.1 Appearance Switch shall have good finishing, and no rust crack or plating failures.
1.3.2 Construction and dimensions Refer to individual product drawing.
3.4. Electrical specifications
NO. |
Items |
Test conditions |
Criteria |
1.4.1 |
Contact |
Shall be measured at 12A 24VDC by voltage drop Applied position: Between terminal and terminal |
30mΩ MAX |
1.4.2 |
Insulation |
Test voltage:500VDC, measured after 1 min ±5s Applied position: 1)Between terminal and terminal 2)Between terminal and ground |
100MΩ MIN |
1.4.3 |
Voltage proof |
Following test voltages shall be applied for 1 min. (Cut-off current:0.5mA) 1)Between terminal and terminal : 2)Between terminal and ground: |
No dielectric breakdown shall occur |
1.5. ENVIRONMENT RESISTANCE
NO. |
Item |
Test conditions |
Criteria |
1.5.1 |
Cold |
After testing at -25±2℃ for 96 h, |
Contact resistance(item 4.1): 100mΩ MAX Insulation resistance (item 4.2): 50MΩ MIN Voltage proof: (item 4.3) No dielectric Operating characteristic Operating characteristic No abnormalities shall be |
1.5.2 |
Dry heat |
After testing at 105±2℃ for 96 h, |
|
1.5.3 |
Damp heat |
After testing at 40±2℃ and 90-95%RH |
|
1.5.4 |
Change of temperature |
After 20 cycles of following conditions the |
|
1.5.5 |
Salt mist |
Switch shall be checked after following lest. 1) Temperature: 35±2℃ 2) Salt solution: 5±1% (solids by mass) 3) Duration: 24±1h After test, salt deposit shall be |
No remarkable corrosion shall be |
1.6. WELDING CHARACTERISTICS
1.6.1 |
Solder ability |
Switch test under such conditions and inspect after. 1)Variable temperature range :235±5℃; 2)Dip time:3±0.5s; |
The area of dip tin |
|||||||||
1.6.2 |
Resistance to |
The switch will be inspect under such conditions below Temperature and impregnated time
|
All of the appearance, |
1.7. ENDURANCE
NO. |
Item |
Test condition |
Criteria |
||||||||||||||||||
1.7.1 |
Endurance (According to UL61058) |
13A 125VAC Switch shall be operated according to following sequence (Test1~Test2)
Voltage proof(Cut-off current:0.5mA) 1GPA 125/250VAC ; Switch shall be operated 6,000 cycles at 15-20 cycles/min. Test voltages shall be applied for 1 min |
Insulation resistance(item 4.2): 30MΩ MIN Voltage proof: Terminal and ground:1000VAC No dielectric breakdown shall occur. Operating characteristic (item 5.1): Operating characteristic variety Within ±20% of specified value . 6000 cycles 10,000 cycles
No abnormalities shall |
||||||||||||||||||
1.7.2 |
Endurance (According to /IEC61058-1) |
10 (8) A 250VAC Switch shall be operated 10,000 cycles at 15~20 cycles/min Voltage proof(Cut-off current:0.5mA) Test voltages shall be applied for 1 min. |
Insulation resistance(item 4.2): 50MΩ MIN Voltage proof: Terminal and terminal:750VAC Terminal and ground:1500VAC No dielectric breakdown shall occur. Operating characteristic (item 5.1): Operating characteristic variety Within ±20% of specified value . Temperature rise:55℃ MAX No abnormalities shall be |
4. DRAWING & DIMENSION:
5. CIRCUIT DIAGRAM:
6. PACKING:
6.1 |
Packing material: |
Plastic bag / |
6.2 |
Packing number: |
100 pieces per bag Each shipping carton 2000 pieces |
6.3 |
Weight: |
Gross Weight: 11.75kg Net Weight: 10.0kg |
6.4 |
Size: |
31 x26 x27 CM /0.022CBM |