+86-0512-62885849

EN
All Categories

Home /Products /Rocker Switch /General Rocker Switch

  • /img/kan-b2-sw25d-r-wp-2-pins-round-spst--on-off-rocker-switch-with-waterproof-cap.jpg

KAN-B2-SW25D-R (WP) 2 pins round SPST ON-OFF rocker switch with waterproof cap

Series:KAN-B2

Quick Detail:

Type:KAN-B2-SW25D-R(WP)

Rating: 10A 125VAC10(6)A 250VAC
Operation method: Rocker Action
Configuration: Single-Pole Single-Through (SPST)
Terminal form: Solder Terminal
Mounting: Snap-In

  • Remarks
  • Technical parameters
Remarks

Technical parameters

1.DETAIL SPECIFICATIONS:
Type:KAN-B2-SW25D-R(WP)
Rating: 10A 125VAC10(6)A 250VAC
Operation method: Rocker Action
Configuration: Single-Pole Single-Through (SPST)
Terminal form: Solder Terminal
Mounting: Snap-In
1.1OPERATING CHARACTERISTICS

Characteristics

Units

Standards

Note

Actuating Force

N

4±2Max

Original 4±2  .

Contact Force

N

0.4 Min

Original 0.4 Min

Electrical Clearance

mm

3 Min

Original 3 Min

Note:
Actuating Force:The force required to move the actuator from the free to the operation position
1.2 GENERAL CHARACTERISTICS
1.2.1Application This specification is applied to KAN Rocker Switch used for electronic equipment.
1.2.2 Operating temperature range -25℃ to +105℃
1.2.3Test conditions Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows  
Ambient temperature:15~35℃
Relative humidity:45~85%
Air pressure:86~106kPa (860~1060 mbar)
Should any doubt arise in judgment. tests shall be conducted at the following conditions.  
Ambient temperature:20±2℃
Relative humidity:60~70%
Air pressure:86~106kPa (860~1060 mbar)
1.3 Appearance construction and dimensions
1.3.1 Appearance Switch shall have good finishing, and no rust crack or plating failures.
1.3.2 Construction and dimensions Refer to individual product drawing.
1.4. Electrical specifications

NO.

Items

Test conditions

Criteria

1.4.1

Contact 

resistance

Shall be measured at 12A 

24VDC by voltage drop 

method after some 

operations without load.

Applied position: 

Between terminal and 

terminal  

100mΩ MAX

1.4.2

Insulation 

resistance

Test voltage:500VDC, 

measured after 1 min 

±5s

Applied position: 1)

Between terminal and 

terminal 

2)Between terminal 

and ground

100MΩ MIN

1.4.3

Voltage 

proof

Following test voltages 

shall be applied for 1 min.

(Cut-off  current:0.5mA)

1)Between terminal and 

terminal :2000VAC/min 

(50~60Hz)

2)Between terminal and 

ground: 2500VAC/min 

(50~60Hz)

No dielectric 

breakdown

shall occur

1.5. ENVIRONMENT RESISTANCE

1.6. WELDING CHARACTERISTICS

 

1.6.1

 

Solder ability

Switch test under such 

conditions and inspect after. 

1)Variable temperature 

range :235±5℃;

2)Dip time:3±0.5s;

 

The area of dip tin 

should capture the 

95% impregnated 

area

 

1.6.2

 

Resistance to 

soldering heat

 

The switch will be inspect 

under such conditions below

Temperature and impregnated time

Trial measure

temperature

(℃)

Time(s)

Slot welding method

260±5

5±1

Soldering method

350±5

3±0.5

 

 

All of the appearance, 

motor functions, 

electrical properties 

are no abnormal.  

1.7. ENDURANCE

NO.

Item

Test condition

Criteria

1.7.1

Endurance

(According to

 UL61058)

13A 125VAC

Switch shall be operated according to 

following sequence

(Test1~Test2)

 

Voltage

Current

Power 

factor

Operation 

rate

Number of

 operation

Test1

125V

13.45A

0.75-0.8

6-10

cycles/min

50cycles

Test2

125V

13A

0.75-0.8

6-10

cycles/min

6000cycles

Voltage proof(Cut-off current:0.5mA)

1GPA 125/250VAC ;

Switch shall be operated 6,000 cycles at 

15-20 cycles/min.

Test voltages shall be applied for 1 min

Insulation 

resistance: 

100MΩ MIN

Voltage 

proof:

Terminal 

and ground:

1000VAC

No dielectric 

breakdown 

shall occur.

Operating 

characteristic :

Operating 

characteristic 

variety 

Within ±20% 

of specified 

value .

6000 cycles 

temperature 

rise:30℃ MAX;

10,000 cycles 

temperature 

rise:55℃ MAX;

 

No 

abnormalities 

shall be 

recognized 

in appearance 

and 

construction

1.7.2

Endurance

(According to 

EN61058-1

/IEC61058-1)

10 (8) A 250VAC

Switch shall be operated 10,000 cycles at 

15~20 cycles/min

Voltage proof(Cut-off current:0.5mA)

Test voltages shall be applied for 1 min.

Insulation 

resistance: 

100MΩ MIN

Voltage proof:

Terminal and 

terminal:750VAC

Terminal and 

ground:1500VAC

No dielectric 

breakdown 

shall occur.

Operating 

characteristic :

Operating 

characteristic 

variety 

Within ±20% 

of specified 

value .

Temperature 

rise:55℃ MAX

No abnormalities 

shall be 

recognized in 

appearance and 

construction

2. DRAWING & DIMENSION:


 

3. Packing

3.1

Packing material:

Plastic bag  
Double-layers paper carton

3.2

Packing number:

100 pieces per bag 
10 bags per inner carton
2 inner cartons per shipping carton

Each shipping carton 2000 pieces

3.3

Weight:

Gross Weight:  13.75kg

Net Weight:   12.56kg  

3.4

Size:

31 x26 x27 CM /0.022CBM

Contact Us