KCD-SW6 side edge terminal ON-ON-OFF SPST rocker switch for power tools
Series:KCD-SW6
Quick Detail:
Type: KCD-SW6
Construction category: D
Operation method: Rocker Action
Configuration: Single-Pole Double-Through (SPDT)
Terminal form: #187 quick-connect Terminal
Mounting: Snap-In
Protection: IP40
- Remarks
- Applications
- Technical parameters
Remarks
-
SAFETY APPROVAL & RATING:
Approved Rating
Mark
Reference No.
8A 250VAC
UL&CUL
E332058
VDE
CQC
NEMKO
SEMKO
FIMKO
DEMKO
CE
16A 125VAC
TUV
R50261877
ENEC
EK
CB
Applications
Home / Household Appliances
Electric kettle, Robot cleaner, Dust catcher, Vacuum cleaner, Coffee maker, Running machine etc.
Electronic Equipment
Toys, Power tools, Car control panel etc.
Medical Equipment
Communication Equipment
Automation Equipment
Automotive Electronics
Instrumentation
Technical parameters
1.DETAIL SPECIFICATIONS:
Type: KCD-SW6
Construction category: D
Operation method: Rocker Action
Configuration: Single-Pole Double-Through (SPDT)
Terminal form: #187 quick-connect Terminal
Mounting: Snap-In
Protection: IP40mm
1.2 Appearance construction and dimensions
1.2.1 Appearance Switch shall have good finishing, and no rust crack or plating failures.
1.2.2 Construction and dimensions Refer to individual product drawing.
1.3. Electrical specifications
No. |
Items |
Test conditions |
Criteria |
3.3.1 |
Contact resistance |
Shall be measured at 1A,5V DC by voltage drop method after some Operations without load. |
15mΩ MAX |
3.3.2 |
Insulation resistance |
Test voltage:500 V DC measured after 1min±5s Applied position:Between all terminals |
100MΩ MIN |
|
Voltage proof |
Following test voltages shall be applied for 1min. (Cut-off current:0.5mA) 1.Between terminals of open contacts:1500V AC(50~60Hz) 2.Between terminals and ground(frame):3000V AC(50~60Hz) |
No dielectric breakdown shall occur. |
1.4 Mechanical specification
No. |
Items |
Test conditions |
Criteria |
1.4.1Operating Features
|
Operating force |
A static load shall be applied to the tip of actuator in operating direction. |
6-13N |
Rotating angle |
Angle from one position to another position. |
0 |
|
1.4.2 |
Dropping |
Freely dropping switch from 0.8m high to cement floor,each respectively falls. |
No abnormalities for terminal and case |
1.4.3 |
Intensity of terminal |
Lead wiring terminal:application of 60N load for 1 min in any director. |
No abnormalities for terminal and case |
1.4.4 |
Vibration |
Switch shall be secured to a testing machine by a normal mounting device and method.Switch shall be measured after following test. (1) Vibration frequency range :10~55Hz (2) Total amplitude :1.5mm (3) Sweep ratio :10~55~10Hz Approx 约:1min (4) Method of changing the sweep vibration frequency:Logarithmic or linear. (5) Direction of vibration:Three perpendicular directions including actuator. (6) Duration:2h each(6h in total) |
Switch shall function properly at rated current. Insulation resistance (Item4.2): 100 MΩ MIN Voltage proof (Item4.3): No dielectric breakdown shall occur. Operating force (Item5.1): Within+10%,-30% of specified value. Shall be free from mechanical abnormalities. |
3.4.5 |
Shock |
Switch shall be measured after following test at the condition of releasing Self-lock. Mounting method:Normal mounting method Acceleration :30g Duration :11ms
Test direction:3 direction Number of shocks:4times per direction (9 times in total)
|
Switch shall function properly at rated current. Insulation resistance (Item4.2):100 MΩ MIN Voltage proof(Item4.3): No dielectric breakdown shall occur. Operating force (Item5.1): Within+10%,-30% of specified value. Shall be free from mechanical abnormalities. |
1.5 Environment resistance
No. |
Items |
Test conditions |
Criteria |
1.5.1 |
Cold |
Voltage proof(Cut-off current:0.5mA) Following test voltages shall be applied for 1min. Between terminals of open contacts : 1500 V AC(50~60Hz) Between terminals and ground(frame) : 3000 V AC(50~60Hz) |
Switch shall function properly at rated current. Insulation resistance: 10 MΩ MIN Voltage proof : No dielectric breakdown shall occur. Operating force Within+10%,-30% of specified value. No abnormalities shall be recognized in appearance and construction. |
1.5.2 |
Dry heat |
Voltage proof(Cut-off current:0.5mA) Following test voltages shall be applied for 1min. Between terminals of open contacts: 1500 V AC(50~60Hz) Between terminals and ground(frame): 3000 V AC(50~60Hz)
|
Switch shall function properly at rated current. Insulation resistance: 10 MΩ MIN Voltage proof : No dielectric breakdown shall occur. Operating force Within+10%,-30% of specified value. No abnormalities shall be recognized in appearance and construction. |
1.5.3 |
Damp heat |
Voltage proof(Cut-off current:0.5mA) Following test voltages shall be applied for 1min. Between terminals of open contacts : 1500 V AC(50~60Hz) Between terminals and ground(frame) : 3000 V AC(50~60Hz) |
Switch shall function properly at rated current. Insulation resistance: 10 MΩ MIN Voltage proof : No dielectric breakdown shall occur. Operating force Within+10%,-30% of specified value. No abnormalities shall be recognized in appearance and construction. |
1.5.4 |
Change of temperature |
70±2℃ Normal room Temperature -25±2℃
Voltage proof(Cut-off current:0.5mA) Following test voltages shall be applied for 1min. Between terminals of open contacts : 1500 V AC(50~60Hz) Between terminals and ground(frame) : 3000 V AC(50~60Hz) |
Switch shall function properly at rated current. Insulation resistance: 10 MΩ MIN Voltage proof: No dielectric breakdown shall occur. Operating force Within+10%,-30% of specified value. No abnormalities shall be recognized in appearance and construction. |
1.6 Endurance
No. |
Items |
Test conditions |
Criteria |
||||||||||||
1.6.1 |
Endurance (According to UL1054) |
8A 250V AC Switch shall be operated 6,000 cycles at 10cycles/min.
Temperature rise Difference between the steady terminal temperature and ambient temperature shall be measured after conducting the rated current. Voltage proof(Cut-off current:0.5mA) Following test voltages shall be applied for 1min. Between terminals of open contacts : 1500 V AC(50~60Hz) Between terminals and ground(frame): 3000 V AC(50~60Hz) |
Switch shall function properly at rated current.
Insulation resistance: 10 MΩ MIN Voltage proof : No dielectric breakdown shall occur. Operating force (Item5.1): Within+10%,-30% of specified value. Temperature rise :45℃ MAX No abnormalities shall be recognized in appearance and construction.
|
2.DRAWING & DIMENSION:
3. CIRCUIT DIAGRAM:
4. PACKING:
4.1 |
Packing material: |
Plastic bag / |
4.2 |
Packing number: |
100 pieces per bag Each shipping carton 2000 pieces |
4.3 |
Weight: |
Gross Weight: 13.5kg Net Weight: 12.0kg |
4.4 |
Size: |
31 x26 x27 CM /0.022CBM |