KFC-V-SW305R SWITECH 3 parallels detector switch with five pins, SMD type, round actuator with 4 positioning pins
Part No: KFC-V-SW305R
Ratings:DC 30V 0.1A
Quick Detail:
2. DETAIL SPECIFICATIONS:
Part No: KFC-V-SW305R
Ratings:DC 30V 0.1A
2.1 General characteristics
This specification is applied to used for potentiometer general application.
2.2 Operating Temperature Range: -10℃to +60℃
Conditions:
Environment Temperature: 15~35℃
Relative Humidity: 25~85%
Atmospheric Pressure: 86~106Kpa (860~1060mbar)
- Remarks
Remarks
2.2. 电气性能Electronic Characteristics
|
條號NO. |
項目 Items |
測試條件 Test conditions |
標準 Criteria |
|
2.2.1 |
接触电阻 Contact Resistance |
|
500mΩ MAX |
|
2.2.2 |
绝缘电阻 Insulation Resistance |
测试相邻引脚之间,引脚与外壳之间的绝缘阻抗(DC 100V). Measurement shall be made between adjacent terminals, between terminal and shell(DC 100V). |
100MΩ MIN |
|
2.2.3 |
耐压 Dielectric Withstand Voltage |
输入一定电压(50-60Hz,电压值 AC 100V)1 分钟,漏电流为0.5mA,测试邻近端子间. Apply certain voltage (50-60Hz,AC 500V) for 1 minute between adjacent contacts of the connector with 0.5mA leakage sensitivity. |
沒有发烧介质击穿现象。 No arcing , break down and damaging insulation. |
2.3. 耐久性 Reliability Trial
|
條號NO. |
項目 Items |
測試條件 Test conditions |
標準 Criteria |
|
2.3.1 |
可焊性试验 Solder ability Test |
端子顶部被浸入焊锡炉中,温度为230±5℃,时间3±0.5 秒. The top of the terminals shall be dipped in the solder bath at 230±5℃ for 3±0.5 seconds. |
引脚至少95%上锡. Ninety-five percent of terminals shall be dipped. |
|
2.3.2 |
寿命试验 Operation Life |
开关在DC 30V 100mA的电阻回路中以约15-20次/分的速度连续被操作。 The switch is continuously operated in a DC 30V 100mA resistor circuit at a speed of approximately 15-20 times per minute. |
寿命: 50,000 次 实验后: 接触电阻:1ΩMax 开关外观及结构无损坏。 Life test:100,000cycles After test: Contact resistance:1Ω Max No abnormalities shall be recognized in appearance and construction. |
|
2.3.4 |
振动Vibration |
根据以下给定条件进行测试: 振动频率范围:10~55~10Hz;振幅(峰-峰):1.5mm 振动方向:包括手柄行程方向在内的三个相互垂直的方 向;测试时间:每个方向2hours . Measurement shall be made following the test set forth below: 1) Vibration frequency range: 10Hz to 55Hz to 10Hz; 2) Amplitude: 1.5mm; 3) Direction of vibration: three mutually perpendicular direction including the direction of stem travel4) Duration: Each 2hours.
|
机械性能、电气性能无异常. There are no abnormalities in mechanical and electrical performance |
|
2.3.5 |
抗冲击性Impact Resistance |
以686縻m/s²(70g)的加速度、11ms作用时间,向包括操作方向在内的垂直6方向分别施加3次冲击试验 At 686 m/s ² Apply 3 impact tests in the vertical 6 directions, including the operating direction, with an acceleration of (70g) and an action time of 11ms |
2.4. 机械性能 Mechanical Characteristics
|
條號NO. |
項目 Items |
測試條件 Test conditions |
標準 Criteria |
|
2.4.1 |
操 作 力 Operation Force |
逐渐施力操作开关手柄,测量开关到达全部工作行程时所需的最大操作力度。 Operate the actuator of the switch and then increase press strength gradually, Measured maximum operation force while the travel of the switch is full. |
30g±20g |
|
2.4.2 |
端子强度Terminal Strength |
在端子顶端向任一方向施加30gf静载荷1分钟,每一端子一次,端子弯曲无妨。 Apply a static load of 30gf in any direction at the top of the terminal for 1 minute, once per terminal, and the terminal bending is not harmful. |
机械性能、电气性能无异常 No abnormalities in mechanical and electrical performance |
|
2.4.3 |
操作部强度Operating Department Strength |
各方向须经受住15秒100gf的静载荷 Each direction must withstand a static load of 100gf for 15 seconds |
|
2.5.耐環境性 Environment Resistance
|
條號NO. |
項目 Items |
測試條件 Test conditions |
標準 Criteria |
|
2.5.1 |
低溫Cold |
在經受-20±2℃,96小時試驗之後,開關在常溫常濕條件下恢復1小時,然後在1小時內完成測量。要除去凝露。 After testing at -40±2℃ for 96 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. water drops shall be removed. |
接觸電阻:500mΩ MAX; Contact resistance: 500mΩMAX;
絕緣電阻:100MΩ MIN; Insulation resistance:100MΩ MIN
耐壓試驗:沒有發生介質擊穿現象; Voltage proof: No dielectric breakdown shall occur.
動作特性:變化值在規定值的±10%以內; Operating characteristic : Operating characteristic variety Within ±10% of specified value .
外觀及結構無異常。 No abnormalities shall be recognized in appearance and construction.
|
|
2.5.2 |
高溫Dry heat |
在經受70±2℃,96小時試驗之後,開關在常溫常濕條件下恢復1小時,然後在1小時內完成測量。 After testing at 85±2℃for 96 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. |
|
|
2.5.3 |
恒定濕熱Damp heat |
在經受溫度為 40±2℃ 相對濕度為 90-95%RH,96小時試驗之後, 開關在常溫常濕條件下恢復1小時,然後在1小時內完成測量。要除去凝露。 After testing at 40±2℃ and 90-95%RH for 96 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. water drops shall be removed. |
3.图纸 Drawing

EN
ES
AR
NL
JA
KO
FR
RU