KFC-W-SW13W-1 Mini Snap Action Switch

Series:KFC

Quick Detail:

Type:KFC-W-SW13W-1
Construction category:D type
Operation method:Snap Action
Configuration:Double-Pole Single -Through (DPST)
Terminal form:PCB Terminal
Protection:Comply with IP40

  • Remarks
  • Applications
  • Technical parameters
Remarks

Material 

No

Name

QTY

Material

1

Case

1

PA66

2

Cover

1

PA66

3

Lug

1

Brass

4

Button

1

PA66

5

Spring

1

Beryllium bronze

6

Contact

1

Ag

7

Lever

1

PA66

Applications

Widely used in home appliance, electronic equipment, automatic machine,
communication equipment, car electron, apparatus and instrument, electric motion tool etc.

Baby chair
CNC machine tools
Power generator
Test equipment

Power tools
Air conditioner
Water heater control panel
Bathroom products

Technical parameters

1.DETAIL SPECIFICATIONS:
Type:KFC-W-SW13W-
Construction category:D type
Operation method:Snap Action
Configuration:Double-Pole Single -Through (DPST)
Terminal form:PCB Terminal
Protection:Comply with IP40

1.1 General
1.1.1 Application This specification is applied to KFC Micro Switch used for electronic equipment.
1.1.2 Operating Temperature range -25℃~+65.
1.1.3 Test condition Unless otherwise specified. The atmospheric conditions for making measurements And tests are as follows:
Ambient temperature: 15~35℃
Relative humidity: 45~85%
Air pressure: 86~106kPa (860~1060 mbar)
Should any doubt arise in judgment. It shall be conducted at the following conditions.
Ambient Temperature: 20±2℃
Relative humidity: 60~70%
Air pressure: 86~106kPa (860~1060 mbar)
1.2 Appearance Construction and Dimension
1.2.1 Appearance Switch shall have good finishing, and no rust crack or plating failures.
1.2.2construction and dimensions Refer to individual product drawing.
 

1.3 Electrical specifications

    

No

Item

Test conditions

Criteria

1.3.1

Contact resistance


At the position of stroke 2.0mm, the voltage drop method is used to measure with 1kHz micro resistance meter (YHP4328A) with current 20mA or DC5V, 1A

 

500mΩ MAX

1.3.2

Insulation resistance

Apply voltage DC100V between terminals for 1 minute ±5 seconds.

100MΩ MIN

1.3.3

Voltage proof

1)Between terminal and terminal :1000VAC (50~60Hz)

2)Between terminal and ground: 3750V AC(50~60Hz)

There was no breakdown of fever mediators.

1.4.  durability

No

Item

Test conditions

Criteria

1.4.1

Electrical life

Under the load of DC30V and 0.1A, open and close test with stroke of 2mm was performed for 20,000 times.

There should be no abnormality in mechanical and electrical properties

1.4.2

Vibration resistance


The vibration tests were carried out in 3 vertical directions for 5 minutes each at a frequency of 10Hz and an amplitude of 2.0mm

 

No mechanical or electrical failure

1.4.3

Resistance to impact

 

Impact tests in 6 vertical directions, including the test direction and the control direction, were carried out with an acceleration of 50G and a time of 11 microseconds. Three tests were conducted in each direction

 

There should be no abnormality in mechanical and electrical properties

1.5. structure and mechanical properties 

No

Item

Test conditions

Criteria

1.5.1

The welding resistance

The switch terminal lasts for 3±1 seconds at 235±5

No deformation or other defects affecting the performance of the switch

1.5.2

Control partial strength

After applying a static load of 3N in each direction for 15 seconds, there should be no abnormal occurrence

1.5.3

Control partial tightness

0.5N static load is applied to the front end of the control component, and the loosening degree in all directions should be within 0.5mm