KW10-ZSW0P150 Mini Snap Action Switch with Arc Zippy Equivalent
Series:KW10
Quick Detail:
Type:KW10-ZSW0P150
Construction category:D type
Operation method:Snap Action
Configuration:Single-Pole Double -Through (SPDT)
Terminal form:PCB Terminal
Mounting:via side mounting holes
Protection:Comply with IP40
- Remarks
- Applications
- Technical parameters
Remarks
PARTS LIST
NO. |
QUANTITY |
Item |
Material |
1 |
1 |
plunger |
Engineering plastic White PBT |
2 |
1 |
cover |
Engineering plastic Black PBT |
3 |
1 |
Moving piece |
Beryllium alloy QBe2 |
4 |
1 |
support |
Brass alloy H65,Silver plated |
5 |
1 |
case |
Engineering plastic White PBT |
6 |
1 |
NO terminal |
Brass alloy H65,Silver plated |
7 |
1 |
contact |
AgNi10 |
8 |
1 |
NC terminal |
AgNi10/Cu |
9 | 1 |
contact |
AgNi10 |
Note: Returned plastic should not exceed 20%.
Approved Rating |
Mark |
Reference No. |
3(0.5)A125/250VAC3GPA125/250VAC3RA125/250VAC40T85,1E4,50-60HzIP403 A, 30 V dc40T85,1E4, IP40 |
UL&CUL |
E176213 |
|
VDE |
|
3(0.5)A250VAC |
CQC |
CQC07002020246 |
|
NEMKO |
|
|
SEMKO |
|
|
FIMKO |
|
3(0.5) A, 125/250 VAC3 RA, 125/250 VAC3 A, 30 V d.c.40T85, 1E4, 50-60Hz, IP40 |
DEMKO |
D-00719 |
3(0.5)A250VAC |
CE |
AN501823730001 |
3(0.5)A250VAC |
TUV |
R50060067 |
3(0.5) A, 125/250 VAC3 RA, 125/250 VAC3 A, 30 V d.c.40T85, 1E4, 50-60Hz, IP40
|
ENEC |
ENEC-00182 |
3(0.5)A250VAC 10E3 T85 |
EK |
SU02030-8001A |
3(0.5) A, 125/250 VAC3 RA, 125/250 VAC3 A, 30 V d.c.40T85, 1E4, 50-60Hz, IP40
|
CB |
DK-5190 |
Applications
Widely used in home appliance, electronic equipment, automatic machine,
communication equipment, car electron, apparatus and instrument, electric motion tool etc.
Baby chair
CNC machine tools
Power generator
Test equipment
Power tools
Air conditioner
Water heater control panel
Bathroom products
Technical parameters
1.DETAIL SPECIFICATIONS:
Type:KW10-ZSW0P150
Construction category:D type
Operation method:Snap Action
Configuration:Single-Pole Double -Through (SPDT)
Terminal form:PCB Terminal
Mounting:via side mounting holes
Protection:Comply with IP40
1.1OPERATING CHARACTERISTICS
Characteristics |
Units |
Standards |
Note |
Actuating Force |
N |
1.5 Max |
Original 1.5 max. |
Release Force |
N |
0.08 Min |
Original 0.08 Min |
Operating Position |
mm |
5.5 ± 0.3 |
Original 5.5 ± 0.3 |
Note:
Actuating Force:
The force required to move the actuator from the free to the operation position
Release Force
The force allowed the mechanism to reset actuator after operation
Free Position
The position of the actuator when no external force is applied
Operating Position
The position of the actuator when contact change-over take place
Movement Differential
The distance between operation and release position
1.2 General
1.2.1 Application This specification is applied to KW10 Micro Switch used for electronic equipment.
1.2.2 Operating Temperature range -40℃ ~ +85℃
1.2.3 Test condition Unless otherwise specified. The atmospheric conditions for making measurements And tests are as follows:
Ambient temperature: 15~35℃
Relative humidity: 45~85%
Air pressure: 86~106kPa (860~1060 mbar)
Should any doubt arise in judgment. It shall be conducted at the following conditions.
Ambient Temperature: 20±2℃
Relative humidity: 60~70%
Air pressure: 86~106kPa (860~1060 mbar)
1.3 Appearance Construction and Dimension
1.3.1 Appearance Switch shall have good finishing, and no rust crack or plating failures.
1.3.2construction and dimensions Refer to individual product drawing.
1.4. Electrical Specifications
NO. |
Item |
Test Condition |
Criteria |
1.4.1 |
Contact Resistance |
Shall be measured at 1A,5V DC by voltage drop method after some operations without load. Applied position: Between terminal “C” and terminal “NO”. |
50mΩ MAX |
1.4.2 |
Insulation Resistance |
Test voltage:500VDC, measured after 1 min ±5s Applied Position: applied position: terminal “NO” 2)Between terminal and ground |
100MΩ MIN |
1.4.3 |
Voltage proof |
Following test voltages shall be applied for 1 min. 1)Between terminal “C” and terminal “NO”:600VAC (50~60Hz) 2)Between terminal and ground: 1000V AC(50~60Hz) |
No dielectric breakdown shall occur |
1.5. Durability
NO. |
Item |
Test Condition |
Criteria |
1.5.1 |
Cold |
After testing at -40±2℃ for 96 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. water drops shall be removed. |
Contact resistance (item 4.1): 100mΩ MAX Insulation resistance (item 4.2): 50MΩ MIN Voltage proof: (item 4.3) No dielectric breakdown shall occur. Within 10% of specified No abnormalities shall be recognized in appearance and construction
|
1.5.2 |
Dry heat |
After testing at 85±2℃ for 96 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. |
|
1.5.3 |
Damp Heat |
After testing at 40±2℃ and 90-95%RH for 96 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. water drops shall be removed. |
|
1.5.4 |
Change of Temperature |
After 5 cycles of following conditions the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. water drops shall be removed. |
|
1.5.5 |
Salt Mist |
Switch shall be checked after following lest. 1) Temperature: 35±2℃ 2) Salt solution: 5±1% (solids by mass) 3) Duration: 24±1h After test, salt deposit shall be removed in running water |
No remarkable corrosion shall be recognized in metal part |
1.6. Welding Performance
1.6.1 |
Solder ability |
Switch test under such conditions and inspect after. 1)Variable temperature range :235±5℃; 2)Dip time:3±0.5s; |
The area of dip tin should capture the 95% impregnated area |
|||||||||
1.6.2 |
Resistance to soldering heat |
The switch will be inspect under such conditions below Temperature and impregnated time
|
All of the appearance, motor functions, electrical properties are no abnormal. |
1.7. Durability
NO. |
Item |
Test Condition |
Criteria |
||||||||||||||||||
1.7.1 |
Endurance (According to UL61058) |
1A 125VAC Switch shall be operated according to following sequence (Test1~Test2)
Voltage proof:Test voltage shall be applied for 1 min(50~60Hz, Cut-off current:0.5mA) 3GPA125/250VAC Operation Cycles:10,000 次 ; Operation Frequency:15~20 次/min Voltage proof:Test voltage shall be applied for 1 min(50~60Hz, Cut-off current:0.5mA)
|
Insulation resistance (item 4.2): 50MΩ MIN; Voltage proof: Terminal and terminal:1000VAC No dielectric breakdown shall occur.
Operating characteristic (item 5.1): Within 20% of specified
6000 cycles temperature rise: 30℃ MAX; 10000cycles temperature rise: 55℃ MAX; No abnormalities shall be recognized in appearance and construction. |
||||||||||||||||||
1.7.2 |
Endurance (According to EN61058-1 /IEC61058-1) |
3(0.5)A250VAC Operating Cycles:10,000 cycles Operation Frequency:15~20 cycles/m 3(0.5)A 250VAC Voltage proof:Test voltage shall be applied for 1 min(50~60Hz, Cut-off current:0.5mA)
|
Insulation resistance (item 4.2): 50MΩ MIN Voltage proof: Terminal and terminal:750VAC Terminal and ground:1500VAC No dielectric breakdown shall occur. Operating characteristic (item 5.1): Within ±20% of specified Temperature rise:55℃ MAX No abnormalities shall be recognized in appearance and construction |
2. DRAWING & DIMENSION
3. CIRCUIT DIAGRAM
4.1 |
Packing material: |
Plastic box / |
4.2 |
Packing number: |
100 pieces per box |
4.3 |
Weight: |
Gross Weight: 8.5kg Net Weight: 7.0kg |
4.4 |
Size: |
31.0 x 25.0 x 34.5 CM / 0.045CBM |