MPS-16SW-ST 16mm flat head stainless steel pushbutton switch with brass terminal
Series:MPS-16SW
Quick Detail:
Type: MPS-16SW-ST
Construction category: D type
Operation method: Push button switch
Configuration: Single-Pole Single -Throw (SPST)
Terminal form: Solder Terminal
Protection: IP65
Ratings: 3A 36VDC
Withstand voltage: 1000VAC,1Min
- Remarks
- Applications
- Technical parameters
Remarks
PARTS LIST:
NO. |
quantity |
Items |
Material |
1 |
1 |
terminal |
Brass sliver or Golden plated |
2 |
1 |
Base |
PC |
3 |
1 |
Button base |
PBT,UL rated 94V-0 |
4 |
1 |
Contact |
Ag ally |
5 |
1 |
actuator |
PC/Stainless Steel |
Note: Returned plastic should not exceed 20%.
Applications
Enormous remote
controller and portable remote controller
Instrumentation
Medical equipment
Telecommunications and networking equipment
Computers & peripherals
Instrumentation and controls
Industrial electronic equipment
Industrial remote controller
Medical Equipment
Communication
Outdoor Controls
Public building, Home security, Business building, Industrial equipment…etc.
Technical parameters
3. DETAIL SPECIFICATIONS:
Type:MPS-16SW-ST
Construction category: D
Operation method: Push button switch
Configuration: Single-Pole Single -Throw (SPST)
Terminal form:Solder Terminal
Protection:IP65
Ratings 3A 36VDC
Withstand voltage 1000VAC,1Min
3.1 General
3.1.1 Application This specification is applied to KAN-J4 Power Switch used for electronic equipment.
3.1.2 Operating temperature range -20℃ to +55℃
3.1.3 Test conditions Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows
Ambient temperature:15~35℃
Relative humidity:45~85%
Air pressure: 86~106kPa (860~1060 mbar)
Should any doubt arise in judgment. tests shall be conducted at the following conditions.
Ambient temperature:20±2℃
Relative humidity:60~70%
Air pressure: 86~106kPa (860~1060 mbar)
3.2Appearance construction and dimensions
3.2.1Appearance Switch shall have good finishing, and no rust crack or plating failures.
3.2.2Construction and dimensions Refer to individual product drawing
3.3. Electrical Characteristics
NO. |
Items |
Test conditions |
3.3.1 |
Contact resistance |
The contact resistance should be 50mΩ(Max). |
3.3.2 |
Insulation resistance |
It is measured with 500V DC 1minute should be 1000MΩ(Min). |
3.3.3 |
Dielectric strength |
AC 1000V,1min.(before endurance test) AC 1000V,1min.(after endurance test) |
3.4 Mechanical Characteristics
Item |
Description |
Test Conditions |
1 |
Operating Force |
450gf-100gf |
2 |
Operating Life |
The mechanical life all of 50 000 cycles |
3 |
Contact Spacing |
Min. 3.0mm (IEC61058) |
3.5Durability
NO. |
Item |
Test condition |
Criteria |
||||||||||||||||||
3.5.1 |
Endurance (According to UL61058) |
3A 36VDC Switch shall be operated according to following sequence (Test1~Test2)
Voltage proof(Cut-off current:0.5mA) 3A 36VDC Switch shall be operated 50,000 cycles at 15-20 cycles/min. Test voltages shall be applied for 1 min |
Insulation resistance(item 4.2): No abnormalities shall be recognized in appearance and construction |
||||||||||||||||||
3.5.2 |
Endurance (According to EN61058-1 /IEC61058-1) |
2A 36VDC Switch shall be operated 50,000 cycles at 15~20 cycles/min Voltage proof(Cut-off current:0.5mA) Test voltages shall be applied for 1 min. |
Insulation resistance(item 4.2): 50MΩ MIN Voltage proof: Terminal and terminal:750VAC Terminal and ground:1500VAC No dielectric breakdown shall occur. |