MPS-16SW-ST 16mm flat head stainless steel pushbutton switch with brass terminal
Series:MPS-16SW
Quick Detail:
Type: MPS-16SW-ST
Construction category: D type
Operation method: Push button switch
Configuration: Single-Pole Single -Throw (SPST)
Terminal form: Solder Terminal
Protection: IP65
Ratings: 3A 36VDC
Withstand voltage: 1000VAC,1Min
- Remarks
- Applications
- Technical parameters
Remarks
PARTS LIST:
|
NO. |
quantity |
Items |
Material |
|
1 |
1 |
terminal |
Brass sliver or Golden plated |
|
2 |
1 |
Base |
PC |
|
3 |
1 |
Button base |
PBT,UL rated 94V-0 |
|
4 |
1 |
Contact |
Ag ally |
|
5 |
1 |
actuator |
PC/Stainless Steel |
Note: Returned plastic should not exceed 20%.
Applications
Enormous remote
controller and portable remote controller
Instrumentation
Medical equipment
Telecommunications and networking equipment
Computers & peripherals
Instrumentation and controls
Industrial electronic equipment
Industrial remote controller
Medical Equipment
Communication
Outdoor Controls
Public building, Home security, Business building, Industrial equipment…etc.
Technical parameters
3. DETAIL SPECIFICATIONS:
Type:MPS-16SW-ST
Construction category: D
Operation method: Push button switch
Configuration: Single-Pole Single -Throw (SPST)
Terminal form:Solder Terminal
Protection:IP65
Ratings 3A 36VDC
Withstand voltage 1000VAC,1Min
3.1 General
3.1.1 Application This specification is applied to KAN-J4 Power Switch used for electronic equipment.
3.1.2 Operating temperature range -20℃ to +55℃
3.1.3 Test conditions Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows
Ambient temperature:15~35℃
Relative humidity:45~85%
Air pressure: 86~106kPa (860~1060 mbar)
Should any doubt arise in judgment. tests shall be conducted at the following conditions.
Ambient temperature:20±2℃
Relative humidity:60~70%
Air pressure: 86~106kPa (860~1060 mbar)
3.2Appearance construction and dimensions
3.2.1Appearance Switch shall have good finishing, and no rust crack or plating failures.
3.2.2Construction and dimensions Refer to individual product drawing
3.3. Electrical Characteristics
|
NO. |
Items |
Test conditions |
|
3.3.1 |
Contact resistance |
The contact resistance should be 50mΩ(Max). |
|
3.3.2 |
Insulation resistance |
It is measured with 500V DC 1minute should be 1000MΩ(Min). |
|
3.3.3 |
Dielectric strength |
AC 1000V,1min.(before endurance test) AC 1000V,1min.(after endurance test) |
3.4 Mechanical Characteristics
|
Item |
Description |
Test Conditions |
|
1 |
Operating Force |
450gf-100gf |
|
2 |
Operating Life |
The mechanical life all of 50 000 cycles |
|
3 |
Contact Spacing |
Min. 3.0mm (IEC61058) |
3.5Durability
|
NO. |
Item |
Test condition |
Criteria |
||||||||||||||||||
|
3.5.1 |
Endurance (According to UL61058) |
3A 36VDC Switch shall be operated according to following sequence (Test1~Test2)
Voltage proof(Cut-off current:0.5mA) 3A 36VDC Switch shall be operated 50,000 cycles at 15-20 cycles/min. Test voltages shall be applied for 1 min |
Insulation resistance(item 4.2): No abnormalities shall be recognized in appearance and construction |
||||||||||||||||||
|
3.5.2 |
Endurance (According to EN61058-1 /IEC61058-1) |
2A 36VDC Switch shall be operated 50,000 cycles at 15~20 cycles/min Voltage proof(Cut-off current:0.5mA) Test voltages shall be applied for 1 min. |
Insulation resistance(item 4.2): 50MΩ MIN Voltage proof: Terminal and terminal:750VAC Terminal and ground:1500VAC No dielectric breakdown shall occur. |
3.6. SOLDERING
Solder ability and Resistance to sold heat according to IEC 68-2-20
4. DRAWING & DIMENSION:
EN
ES
AR
NL
JA
KO
FR
RU