+86-0512-62885849

EN
All Categories

Home /Products /Micro Switch /General Micro Switch

  • /img/ms10-10zswc-c040-02-micro-switch-spdt-customized-lever-arm.jpg

MS10-10ZSWC-C040-02 Micro Switch SPDT Customized Lever/Arm

Series:MS10 series

Quick Detail:

Type:MS10-10ZSWC-C040-02
Construction category:D type
Operation method:Snap Action
Configuration:Single-Pole Double -Throw (SPDT)
Terminal form:#250 Quick-connect Terminal
Mounting:via side mounting holes
Protection:IP40

  • Remarks
  • Applications
  • Technical parameters
Remarks

SAFETY APPROVAL & RATING:

Approved Rating

Mark

Reference No.

10A 125V/250V AC 1/4hp 250V AC 1/2hp 125V AC 1E4 T125

10(3)A 125/250V AC 10GPA,125/250V AC,1/3hp 125/250V AC, 6A 30VDC 50-60Hz 25T105 5E4

UL&CUL

E176213

 

VDE

 

10(3)A 125V/250V AC 5E4 25T105

CQC

CQC10002048742

 

NEMKO

 

 

SEMKO

 

 

FIMKO

 

10(3)A 125V/250V AC 6A 30VDC 50-60Hz 5E4 25T105 IP40

DEMKO

D-00720

 

CE

 

 

TUV

 

10(3)A 125V/250V AC 6A 30VDC 50-60Hz 5E4 25T105 IP40

ENEC

ENEC-00183

 

EK

 

10(3)A 125V/250V AC 6A 30VDC 50-60Hz 5E4 25T105 IP40

CB

DK-5193

 

6. PARTS LIST

NO

Item

Material

1

cover

Plastic PA66 Black

2

Terminal

Brass alloy H65 , Silver plated

3

Terminal

Brass alloy H65 , Silver plated

4

case

Plastic PA66 Black

5

Contact

AgNi10/Cu

6

Contact

AgCd12/Cu

7

Plate moving

Beryllium Bronze

8

Terminal

Brass alloy H65 , Silver plated

9

Button

Plastic PA66 Black

10

Spring

Stainless steel SUS304H

11

Moving arms

Stainless steel SUS304

Note: Returned plastic should not exceed 20%.

Applications

Widely used in home appliance, electronic equipment, automatic machine, communication equipment, car electron, apparatus and instrument, electric motion tool etc.

Rice cooker
Slow cooker
Electric Heating Faucet

Electromagnetic lock
Baby chair
CNC machine tools
Power generator
Test equipment

Water heater control panel
Bathroom products
Vacuum cleaner
Kitchen products

Technical parameters

3.DETAIL SPECIFICATIONS
Type::MS10-10ZSWC-C040-02
Construction category:D type
Operation method:Snap Action
Configuration:Single-Pole Double -Throw (SPDT)
Terminal form:#250 Quick-connect Terminal
Mounting:via side mounting holes
Protection:IP40
3.1OPERATING CHARACTERISTICS

Characteristics

Units

Standards

Note

Actuating Force

N

0.16 Max

Original 0.16 Max

Release Force

N

0.02 Min

Original 0.02 Min

Operating Position

mm

14.5 ± 1

Original 14.5 ± 1

Note:
Actuating Force:
The force required to move the actuator from the free to the operation position
Release Force
The force allowed the mechanism to reset actuator after operation
Free Position
The position of the actuator when no external force is applied
Operating Position
The position of the actuator when contact change-over take place
Movement Differential
The distance between operation and release position 


3.2 General
3.2.1 Application This specification is applied to MS10 Micro Switch used for electronic equipment.
3.2.2 Operating Temperature range -25℃ ~ +105℃
3.2.3 Test condition Unless otherwise specified. The atmospheric conditions for making measurements And tests are as follows:
Ambient temperature: 15~35℃
Relative humidity: 45~85%
Air pressure: 86~106kPa (860~1060 mbar)
Should any doubt arise in judgment. It shall be conducted at the following conditions.
Ambient Temperature: 20±2℃
Relative humidity: 60~70%
Air pressure: 86~106kPa (860~1060 mbar)
3.3 Appearance Construction and Dimension
3.3.1 Appearance Switch shall have good finishing, and no rust crack or plating failures.
3.3.2construction and dimensions Refer to individual product drawing.
3.4.Electrical Specifications

NO.

Item

Test Condition

Criteria

3.4.1

Contact Resistance

Shall be measured at 1A,5V DC by

 voltage drop method after some operations 

without load.

Applied position: Between terminal

 “C” and terminal “NO”.

100mΩ MAX

3.4.2

Insulation Resistance

Test voltage:500VDC, measured after 1 min ±5s

Applied Position: applied position: 
1)Between terminal “C” and terminal “NO”

2)Between terminal and ground

100MΩ MIN

3.4.3

Voltage proof

Following test voltages shall be applied for 1 min.

1)Between terminal “C” and terminal

 “NO”:1000VAC (50~60Hz)

2)Between terminal and ground: 1500V AC(50~60Hz)

No dielectric 

breakdown 

shall occur

3.5. Durability

NO.

Item

Test Condition

Criteria

3.5.1

Cold

After testing at -25±2℃ for 96 h, 

the switch shall be allowed to stand 

under normal room temperature 

and humidity condition for 1h, and 

then measurement shall be made 

within 1 h. water drops shall be 

removed.

Contact 

resistance

(item 4.1): 

100mΩ 

MAX

Insulation 

resistance 

(item 4.2):

50MΩ MIN

Voltage 

proof: 

(item 4.3)

No dielectric 

breakdown 

shall occur.

Within 10%

 of specified
value .

No 

abnormalities 

shall be 

recognized 

in appearance 

and construction

 

3.5.2

Dry heat

After testing at 105±2℃ for 96 h, 

the switch shall be allowed to stand 

under normal room temperature 

and humidity condition for 1h, and 

then measurement shall be made 

within 1 h.

3.5.3

Damp Heat

After testing at 40±2℃ and 90-95%RH 

for 96 h, the switch shall be 

allowed to stand under normal room 

temperature and humidity 

condition for 1h, and then 

measurement shall be made within 1 h. 

water drops shall be removed.

3.5.4

Change of Temperature

After 5 cycles of following conditions 

the switch shall be allowed to 

stand under normal room 

temperature and humidity condition for 

1h, and then measurement shall

 be made within 1 h. water drops 

shall be removed.

3.6 Durability

NO.

Item

Test Condition

Criteria

 

3.6.1

 

Endurance

(According to

 UL61058)

 

1/3hp 125VAC

Switch shall be operated according to following sequence

(Test1~Test2)

 

Voltage

Current

Power Factor

Operation Rate

Operation Cycles

Test 1

125V

43.2 A

0.4-0.5

6-10Cycles/min

50cycles

Test2

125V

7.2 A

0.7-0.8

6-10Cycles/min

10000cycles

Voltage proof:Test voltage shall be applied for 1 min(50~60Hz, Cut-off current:0.5mA)

10GPA 125/250VAC;

Operation Cycles:10,000 次 ;

Operation Frequency:15~20 次/min

Voltage proof:Test voltage shall be applied for 1 min(50~60Hz, Cut-off current:0.5mA)

 


 

Insulation 

resistance

(item 4.2):

50MΩ MIN

Voltage proof:

Terminal and 

terminal:1000

VAC

No dielectric 

breakdown 

shall occur.

 

Operating 

characteristic 

(item 5.1):

Within 20% 

of specified
value .

 

6000 cycles 

temperature 

rise: 30℃ MAX

10000cycles 

temperature 

rise: 55℃ MAX

No abnormalities 

shall be 

recognized 

in appearance 

and construction.

 

3.6.2

 

Endurance

(According 

to EN61058-1

/IEC61058-1)

 

10(3)A 125/250VAC; 8A 30VDC

Operating Cycles:10,000 cycles

Operation Frequency:15~20 cycles/m

Voltage proof:Test voltage shall be applied for 1 min(50~60Hz, Cut-off current:0.5mA)

 

 

Insulation 

resistance

(item 4.2): 

50MΩ MIN

Voltage 

proof:

Terminal and 

terminal:750VAC

Terminal and 

ground:1500VAC

No dielectric 

breakdown shall 

occur.

Operating 

characteristic 

(item 5.1):

Within ±20% 

of specified
value .

Temperature 

rise:55℃ MAX

No 

abnormalities 

shall be 

recognized 

in appearance 

and 

construction

4. DRAWING & DIMENSION

5. CIRCUIT DIAGRAM

7.  PACKING:

7.1

 Packing material:

Plastic box / 
Double-layers paper carton

7.2

 Packing number:

625 pieces per box
4 inner cartons per shipping carton
Each shipping carton 2500 pieces

7.3

Weight:

Gross Weight:  8.5kg

 Net Weight:  7.0kg

7.4

 Size:

31.0 x 25.0 x 34.5 CM / 0.045CBM

Contact Us