+86-0512-62885849

EN
All Categories

Home /Products /Toggle Switch

  • /img/1ms1swt8b13m2qes-5-1ways-3-pins-metal-on-none-on-rocker-arms-toggle-switch.jpg

1MS4SWT8B13M2QES-5 1Ways 3 Pins Metal monentry ON-OFF-ON Rocker Arms Toggle Switch

Series:1MS4SWT8B13M2QES-5

Quick Detail:

Type:      1MS4SWT8B13M2QES-5

Rating:    5A/120VAC/28VDC, 2A/250VAC

Function: 1P2T

  • Remarks
  • Applications
  • Technical parameters
Remarks

PART LIST:

NO

quantity

name

Material Science

1

1

Case

Phthalate(DAP)(UL94V-0) 

2

1

Actuator

Brass, chrome plated.

3

1

Bushing

Brass, nickel plated.  

4

1

Housing

Stainless Steel.

5

3

Contact /Terminal 

Brass, gold plated

6

1

Switch Support

Brass, tin plated

Applications

1.Digital Products: digital camera, digital video and so on;   

2.Remote Control: the remote control of automobile domestic security products;   

3.Communication Products: mobile phone, vehicle-mounted phone, telephone set, building equipment, PDA and so on;  
                                             
4.Homehole appliances: TV set, microwave oven, electric rice cooker, electric fans ,refrigerator,washer;air-conditioning and so on;   
                                                                              
5.Security Products: visual interphone, monitor and so on;   
                      
6.Toys: electric toys and so on;   

7.Computer Products: PC camera and so on;   

8.Exercises Machines: treadmills, massage armchair and so on;                                                                    

9.Medical Device: sphygmomanometer, thermometer, hospital call system and so on;
      
10.Others:  laser pen ,Pointer,Wireless mouse remote control pen,Laser projection pen,page turner,electronic pen;MousePen;overhead projector and so on;

11.Operating switches in all types of electronic equipment such as audio devices, office devices, communication devices, measuring instruments, TVs, video recorders,automotive sets, etc.

12.Household appliances, electric force, telecommunications, machine tool, vessel, textile, printing, Mining machine,  Music Instrument, etc.

Technical parameters

1. DETAIL SPECIFICATIONS:

Type:      1MS4SWT8B13M2QES-5

Rating:    5A/120VAC/28VDC, 2A/250VAC

Function: 1P2T

1.1 OPERATING CHARACTERISTICS

NO.

ITEM

TEST CONDITIONS

PERFORMANCE

1.1.1

Operating Force

The test point is 3mm away from the rubber handle. After three times, the test is carried out.

400gf±100gf

1.1.2

Terminal Strength

In the front row of feet, any square type plus (500gf) strength test will take 15 seconds.

There are no cracks, loosening and other abnormalities in the terminals to meet the mechanical and electrical properties.

1.1.3

Shank strength

The force of 1Kgf is applied at the front of the handle, and the displacement should be fixed along the direction of the mark.

There is no serious deformation of the handle, and it can work normally.

Actuating Force:

The force required to move the actuator from the free to the operation position

1.2 GENERAL CHARACTERISTICS

1.2.1 Application:This specification is applied to 1MS4 Toggle Switch used for electronic equipment.

1.2.2 Operating temperature range: -40℃ + 85℃

1.2.3 Test conditions : Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows  

Ambient temperature:                     15~35℃

Relative humidity:                           45~85%

Air pressure:                                  86~106kPa (860~1060 mbar)

1.3 APPEARANCE, STRUCTURE AND DIMENSION

1.3.1 Appearance :Switch shall have good finishing, and no rust crack or plating failures.

1.3.2 Construction and dimensions: Refer to individual product drawing.

1.4 Electrical specifications

NO.

ITEM

TEST CONDITIONS

PERFORMANCE

1.4.1

CONTACT

RESISTANCE

The 2-4VDC is tested under tiny current (below 100mA), silver plated or gold plated.

10mΩ MAX

1.4.2

INSULATION

RESISTANCE

Measurements shall be made following application of 1000V/DC 100mA potential across terminals and cover for 1 minute.

1000MΩ MIN

1.4.3

Pressure resistance

1000V AC(50Hz or 60Hz)0.5mA shall be applied across terminals and cover for 1minute.

There shall be no breakdown or flashover.

1.5 Endurance

NO.

ITEM

TEST CONDITIONS

PERFORMANCE

1.5.1

Life Test

Measurement under the following test:

(1) 5A 120VAC Resistive load - Plate with silver

2A 250VAC Resistive load - Plate with silver

0.4A 20VAC Resistive load - Plate with gold

(2)Operating frequency:The frequency of 6-8 times per minute

(3)Electrical life 6,000 make-and-break cycles.

(4)Mechanical life 40,000 make-and-break cycles.

(1) contact resistance:10 mΩ MAX

(2) insulation resistance: 1000 MΩ MIN

(3) Insulation strength:1000V

(4) After testing, the appearance is free from damage and meets mechanical properties.

1.5.2

Solder heat resistance

①Manual Soldering:

Soldering Temperature:Max.350℃

Continuous Soldering Time:

Max. 5 seconds.

②WAVE Soldering :

Soldering Temperature:260±5℃.

Duration of Solder Immersion:

5 ±1 seconds

 

③Frequency of Soldering Process 2 times max.(PCB is 1.6mm in thickness)

Precautions in Handling

Care should be exercised so that flux from the upper part of the printed circuit board does not adhere to the switch.

①Shall be free from pronounced backlash and falling-off or breakage terminals.

②As shown in item 3.4.

1.5.3

Resistance Humidityt

Following the test set forth below the sample shall be left in normal temperature and humidity conditions for an hour before the measurements are made:

Temperature:40±2℃

Relative Humidity:90~95%

Time:96 hours.

As shown in item 3.4.

1.5.4

Resistance High Temperature

Following the test set forth below the sample shall be left in normal temperature and humidity conditions for an hour before the measurements are made:

Temperature:85±2℃

Time:96 hours.

1.5.5

Resistance Low Temperature

Following the test set forth below the sample shall be left in normal temperature and humidity conditions for 1 hour before the measurements are made:

Temperature:-40±3℃

Time:96 hours.

1.5.6

The Salt Testing

Following the test set forth below the sample shall be left in normal temperature and humidity conditions for an hour before the measurements are made:

Temperature:35±2℃

The ratio of salt-water:5%

The spray amount of salt- water:

1~2 ml/h.

Time:48 hours.

The testing standard based on bubble, crack, And magnifying glass with gauge.

1.6 SAFEKEEPING METHOD 

(1)If the product is not used immediately, it should be kept at normal temperature without direct sunlight and corrosive gases.

In the environment. But we recommend that we use it as soon as 6 months.

(2)Put the finished products in plastic bags and seal them in the same environment as soon as possible, and use them as soon as possible. Do not overlay excess when saved in order to prevent the pressure from breaking.

(3)Do not overlay excess when saved in order to prevent the pressure from breaking.

1.7 SAFEKEEPING METHOD:

(1)If the product is not used immediately, it should be kept at normal temperature without direct sunlight and corrosive gases.

In the environment. But we recommend that we use it as soon as 6 months.

(2)Put the finished products in plastic bags and seal them in the same environment as soon as possible, and use them as soon as possible. Do not overlay excess when saved in order to prevent the pressure from breaking.

(3)Do not overlay excess when saved in order to prevent the pressure from breaking.

2. DRAWING & DIMENSION:

3.CIRCUIT DIAGRAM:

Contact Us