MW22-A0F1L624-B3ZA SUS304 waterproof metal push button switch with 25A
Series:MW22 series
Quick Detail:
Type: MW22-A0F1L624-B3ZA
Construction category: D type
Operation method: Push button switch
Configuration: Single-Pole Single -Throw (SPST)
Terminal form: Solder Terminal
Protection: IP67
Ratings: 16A 250VAC
Withstand voltage: 1000VAC,1Min
- Remarks
- Applications
- Technical parameters
Remarks
SAFETY APPROVAL & RATING:
Approved Rating |
Mark |
Reference No. |
16A 250VAC |
UL&CUL |
|
|
VDE |
|
|
CQC |
|
PARTS LIST:
Note: Returned plastic should not exceed 20%.
NO. |
quantity |
Items |
Material |
1 |
1 |
Bushings |
Stainless steel |
2 |
1 |
Base |
PBT; PC; PA6T |
3 |
1 |
Actuator |
PC; Stainless steel |
4 |
1 |
Inner assembly |
POM/PA66 |
5 |
1 |
Spring |
Steel |
6 | 1 |
Sealing |
Silicone |
7 | 1 |
O-ring |
Silicone |
8 | 1 |
Terminal |
Brass silver plated |
9 | 1 |
Hex nut |
Nickel plated brass |
Applications
Enormous remote
controller and portable remote controller
Instrumentation
Medical equipment
Telecommunications and networking equipment
Computers & peripherals
Instrumentation and controls
Industrial electronic equipment
Industrial remote controller
Medical Equipment
Communication
Outdoor Controls
Public building, Home security, Business building, Industrial equipment…etc.
Technical parameters
3.1 General
3.1.1 Application This specification is applied to KAN-J4 Power Switch used for electronic equipment.
3.1.2 Operating temperature range -25℃ to +85℃
3.1.3 Test conditions Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows
Ambient temperature: 15~35℃
Relative humidity: 45~85%
Air pressure: 86~106kPa (860~1060 mbar)
Should any doubt arise in judgment. tests shall be conducted at the following conditions.
Ambient temperature: 20±2℃
Relative humidity: 60~70%
Air pressure: 86~106kPa (860~1060 mbar)
3.2Appearance construction and dimensions
3.2.1 Appearance Switch shall have good finishing, and no rust crack or plating failures.
3.2.2Construction and dimensions Refer to individual product drawing.
3.3. Electrical Characteristics
NO. |
Items |
Test conditions |
3.3.1 |
Contact resistance |
The contact resistance should be 100mΩ(Max). |
3.3.2 |
Insulation resistance |
It is measured with 500V DC 1minute should be 100MΩ(Min). |
3.3.3 |
Dielectric strength |
AC 1000V,1min.(before endurance test) AC 2000V,1min.(after endurance test) |
3.4 Mechanical Characteristics
Item |
Description |
Test Conditions |
1 |
Operating Force |
1.5N~3.5N |
2 |
Operating Life |
The mechanical life all of 50 000 cycles |
3 |
Contact Spacing |
Min. 3.0mm (IEC61058) |
3.5Durability
NO. |
Item |
Test condition |
Criteria |
||||||||||||||||||
3.5.1 |
Endurance (According to UL61058) |
16A 250VAC Switch shall be operated according to following sequence (Test1~Test2)
Voltage proof(Cut-off current:0.5mA) 16A 250VAC Switch shall be operated 50,000 cycles at 15-20 cycles/min. Test voltages shall be applied for 1 min |
Insulation resistance(item 4.2): 50MΩ MIN Voltage proof: Terminal and ground:1000VAC No dielectric breakdown shall occur. Operating characteristic (item 5.1): Operating characteristic variety Within ±20% of specifiedvalue . 6000 cycles temperature rise:45℃MAX; 10,000 cycles temperature rise:55℃ MAX;
No abnormalities shall be recognized in appearance and construction |
||||||||||||||||||
3.5.2 |
Endurance (According to EN61058-1 /IEC61058-1) |
16A 250VAC Switch shall be operated 50,000 cycles at 15~20 cycles/min Voltage proof(Cut-off current:0.5mA) Test voltages shall be applied for 1 min. |
Insulation resistance(item 4.2): 50MΩ MIN Voltage proof: Terminal and terminal:750VAC Terminal and ground:1500VAC No dielectric breakdown shall occur. Operating characteristic (item 5.1): Operating characteristic variety Within ±20% of specifiedvalue . Temperature rise:55℃ MAX No abnormalities shall be recognized in appearance and construction |
3.6. SOLDERING
Solder ability and Resistance to sold heat according to IEC 68-2-20
4.DRAWING & DIMENSION: