+ 86-0512-62885849

EN
Alle categorieën

Home /Producten /Drukknopschakelaar /Algemene drukknopschakelaar

PS-12E15 enkelpolige drukknop met 3-pennen

Serie:PS-12E05 series

Quick Detail:

This specification is applied to PS-22E15 Power Switch used for electronic equipment.
Operating temperature range: -10℃ to +85℃
Test conditions Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows
Omgevingstemperatuur: 15 ~ 35 ℃
Relatieve vochtigheid: 45 ~ 85%
Luchtdruk: 86 ~ 106kPa (860 ~ 1060 mbar)

Opmerkingen

GOEDKEURING EN BEOORDELING:

Goedgekeurde beoordeling

Markeer

Referentienummer.

TV8/120VAC TV-8 125VAC 10T85 10GPA 125/250VAC 10A 125/250VAC

1E4 10T85

UL & CUL

E176213

4A/128A 250VAC 10T85 1E4

VDE

129571

8A/128A 250VAC 1E4

CQC

CQC02002002689

4A/128A 250VAC 10T85 1E4

NEMKO

P10213186

4A/128A 250VAC 10T85 1E4

SEMKO

1021831

4A/128A 250VAC 10T85 1E4

FIMKO

261487

4A/128A 250VAC 10T85 1E4

DEMKO

314333-02 D-03541

4A/128A 250VAC 10T85 1E4

CE

SH10041366-V1

TUV

10A 125/250VAC 1E4 10T85

ENEC

ENEC-00946

4/128A 250VAC 10T85 1E4

EK

SU0230-7006A

10A 125/250VAC 1E4 10T85

CB

SE-51323 DK-40111-UL

ONDERDELEN LIJST:

NO.

hoeveelheid

Naam

Materiaal

1

1

KONB

POM

2

1

BLOCK

STAAL STRIP

3

1

LENTE

SUS

4

1

CAM STICK

PBS WIRE

5

1

SPRING PLATE

PBS STRIP

6

1

FRAME

STAAL STRIP

7

1

BASE

FENOLHARS

8

1

TERMINAL

MESSINGSTREEP

9

1

CONTACT

PBS C5210R-EH

Geretourneerd plastic mag 20% niet overschrijden.

toepassingen

This specification is applied to PS-12E05 Power Switch used for electronic equipment.
Operating temperature range -10℃ to +85℃

Test conditions Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows
Omgevingstemperatuur 15 ~ 35 ℃

Technische parameters

3 Algemeen
3.1.1 Application This specification is applied to PS-22E05 Power Switch used for electronic equipment.
3.1.2 Operating temperature range -10℃ to +85℃
3.1.3 Testomstandigheden Tenzij anders aangegeven. De atmosferische omstandigheden voor het uitvoeren van metingen en tests zijn als volgt
Omgevingstemperatuur: 15 ~ 35 ℃
Relatieve vochtigheid: 45 ~ 85%
Luchtdruk: 86 ~ 106kPa (860 ~ 1060 mbar)
Mocht er twijfel ontstaan ​​in het oordeel. tests worden uitgevoerd onder de volgende omstandigheden.
Omgevingstemperatuur: 20 ± 2 ℃
Relatieve vochtigheid: 60 ~ 70%
Luchtdruk: 86 ~ 106kPa (860 ~ 1060 mbar)
3.2 Uiterlijkconstructie en afmetingen
3.2.1 uiterlijkschakelaar moet een goede afwerking hebben en geen roestscheuren of plateringsfouten.
3.2.2 Constructie en afmetingen Raadpleeg de afzonderlijke producttekening.
Trip 2.5±0.5mm
Contact pressure ≥0.4N
The deviation in contact center no large than a quarter of contact diameter
Gap≥2.5mm
Drive type Press button kind, self-lock singe reset mechanical system


3.3. Electrical specifications

NO.

items

Test voorwaarden

criteria

3.3.1

Contact weerstand

MEASURED AT 1 KHz SMALL CURRENT(100 mA OR LESS)

30mΩ MAX

30毫欧以下。

3.3.2

Isolatie weerstand

APPLY A VOLTAGE OF 500V DC SHALL BE APPLIED FOR 1 MIN AFTER WHICH MEASUREMENT BE MADE:

(1) BETWEEN TERMINAL.

(2) BETWEEN INDIVIDUAL TERMINAL AND FRAME.

100MΩ MIN

3.3.3

Spanningsbestendig

AC 500V rms(50~60Hz) FOR 1 MIN TRIP CURRENT: 0.5 mA

1)BETWEEN TERMINAL.

2)BETWEEN INDIVIDUAL TERMINAL AND FRAME.

WITHOUT DAMAGE TO

PARTS ARCING OR BREAKDOWN ETC.

3.4 Mechanical characteristic

item

Beschrijving

Test voorwaarden

Normen

1

Terminal strength

A STATIC LOAD OF 300 gf SHALL BE APPLIED TO THE TERMINAL FOR 15 SEC. IN ANY DIRECTION.

THERE SHALL BE NO DAMAGE TO THE TERMINAL SUCH AS

CRACKS, LOOSENESS OR PLAY.ELECTRICAL AND MECHANICALCHARACTERISTICS SHALL BE SATISFIED.

2

DISPLACEMENT OF ACTUATOR

(KNOB)

A STATIC LOAD OF 10N(1Kgf)SHALL BE APPLIED TO THE TOP OF

THE ACTUATOR(KNOB) AND THEN DISPLACEMENT SHALL BE

MEASURED TO THE DIRECTION OF THE ARROW.

THE LEVER SHALL HAVE NO ANFUNCTION IS NORMALLY.

3

LIFE TEST

WITHOUT LOAD: AN ACTUATOR SHALL BE SUBJECT TO 10,000 CYCLES AT A SPEED OF

15~18 CYCLES FOR 1 MIN.

1)CONTACT RESISTANCE 100 mΩ MAX

2)INSULATION RESISTANCE

50MΩ MIN.

3)WITHSTAND VOLTAGE

AC 500V, 1 MINUTE.

(4)OPERATING FORCE

±30% INITIAL VALUE.

(5)WITHOUT DAMAGE TO

PARTS ARCING OR BREAKDOWN ETC.

3.5. Duurzaamheid

NO.

item

Test voorwaarden

criteria

3.5.1

VOCHTIGHEID

THE JACK SHALL BE STORED AT A TEMPERATURE OF 40±2 °C AND A

HUMIDITY OF 90% TO 95% FOR 96 Hr . THEN THE JACK SHALL BE

MAINTAINED AT STANDARD ATMOSPHERIC CONDITION FOR 1 Hr FOR

OTHER PROCEDURES.

3.5.2

STANDAARD

ATMOSPHERIC

VOORWAARDEN

UNLESS OTHERWISE SPECIFIED. THE STANDARD RANGE OF ATMOSPHERIC CONDITIONS FOR MAKING

MEASUREMENTS AND TESTS ARE AS FOLLOWS:

(1) AMBIENT TEMPERATURE : 5 °C TO 35 °C

(2) RELATIVE HUMIDITY: 45% TO 85%

(3) AIR PRESSURE 86Kpa TO 106Kpa

3.5.3

PRAKTISCH

TEMPERATUUR

RANG

-16 °C ~ +60°C

3.5.4

STORAGE METHOD

(1) IF DON'T USE THE PRODUCT IMMEDIATELY,STORE IT AS DELIVERED IN

THE FOLLOWING ENVIRONMENT: WITH NEITHER DIRECT SUNSHINE NOR

CORROSIVE GAS AND IN NORMAL TEMPERATURES. HOWEVER, IT IS

RECOMMENDED THAT YOU SHOULD USE IT AS SOON AS POSSIBLE BEFORE

SIX MONTHS PASS.

(2) AFTER BREAK THE SEAL,IT SHOULD PUT THE REMAINING IN A

PLASTIC BAG TO SEPARATE IT FROM THE OUTSIDE AND STORE IN THE

SAME ENVIRONMENT MENTIONED ABOVE. YOU SHOULD USE IT UP AS

SOON AS POSSIBLE.

(3) DO NOT STACK TOO MANY SWITCHES FOR STRAFE.

3.6. Lasprestaties

3.6.1

Soldeer vermogen

THE TOP OF THE TERMINALS SHALL BE DIPPED 2mm IN THE SOLDER

BATH OF 230±5 °C FOR 3±0.5 SECONDS.

The area of dip tin should capture the 75% impregnated area

3.6.2

Weerstand tegen soldeerhitte

The switch will be inspect under such conditions below

Temperatuur en geïmpregneerde tijd

Trial measure

temperatuur (℃)

Keer)

Slot welding method

260 ± 5

3 ± 1

Soldering method

360 ± 5

3 ± 1

(2) TMMERSION DEPTH:

IMMERSION DEPTH UP TO THE SURFACE OF THE BOARD THICKNESS OF

PRINTED WIRING BOARD 1.6 mm.

WITHOUT DEFORMATION OF CASE OR EXCESSIVE

LOOSENESS OFTERMINALS

MECHANICAL AND ELECTRICAL

CHARACTERISTICS SHALL BE SATISFIED.

3.6.3

HEAT TEST

THE JACK SHALL BE STORED AT A TEMPERATURE OF 70±2 °C FOR 48 HOURS AND THEN IT SHALL BE SUBJECTED TO THE CONTROLLED RECOVERY CONDITIONS FOR 1 HOUR AFTER WHICH MEASUREMENT SHALL BE MADE.

3.6.4

COLD TEST

THE JACK SHALL BE STORED AT A TEMPERATURE OF -25±3 °C FOR 48 HOURS AND THEN IT SHALL BE SUBJECTED TO THE CONTROLLED RECOVERY CONDITIONS FOR 1 HOUR AFTER WHICH MEASUREMENT SHALL BE MADE.


4. TEKENING & AFMETING:



5. SCHAKELSCHEMA: