PS-12E15 single pole momentary push button switch with 3 pins
Series:PS-12E05 series
Quick Detail:
This specification is applied to PS-22E15 Power Switch used for electronic equipment.
Operating temperature range: -10℃ to +85℃
Test conditions Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows
Ambient temperature: 15~35℃
Relative humidity: 45~85%
Air pressure: 86~106kPa (860~1060 mbar)
- Remarks
- Applications
- Technical parameters
Remarks
-
SAFETY APPROVAL & RATING:
Approved Rating
Mark
Reference No.
TV8/120VAC TV-8 125VAC 10T85 10GPA 125/250VAC 10A 125/250VAC
1E4 10T85
UL&CUL
E176213
4A/128A 250VAC 10T85 1E4
VDE
129571
8A/128A 250VAC 1E4
CQC
CQC02002002689
4A/128A 250VAC 10T85 1E4
NEMKO
P10213186
4A/128A 250VAC 10T85 1E4
SEMKO
1021831
4A/128A 250VAC 10T85 1E4
FIMKO
261487
4A/128A 250VAC 10T85 1E4
DEMKO
314333-02 D-03541
4A/128A 250VAC 10T85 1E4
CE
SH10041366-V1
TUV
10A 125/250VAC 1E4 10T85
ENEC
ENEC-00946
4/128A 250VAC 10T85 1E4
EK
SU0230-7006A
10A 125/250VAC 1E4 10T85
CB
SE-51323 DK-40111-UL
PARTS LIST:
NO.
quantity
Name
Material
1
1
KONB
POM
2
1
BLOCK
STEEL STRIP
3
1
SPRING
SUS
4
1
CAM STICK
PBS WIRE
5
1
SPRING PLATE
PBS STRIP
6
1
FRAME
STEEL STRIP
7
1
BASE
PHENOLIC RESIN
8
1
TERMINAL
BRASS STRIP
9
1
CONTACT
PBS C5210R-EH
Returned plastic should not exceed 20%.
Applications
This specification is applied to PS-12E05 Power Switch used for electronic equipment.
Operating temperature range -10℃ to +85℃
Test conditions Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows
Ambient temperature 15~35℃
Technical parameters
3 General
3.1.1 Application This specification is applied to PS-22E05 Power Switch used for electronic equipment.
3.1.2 Operating temperature range -10℃ to +85℃
3.1.3 Test conditions Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows
Ambient temperature:15~35℃
Relative humidity:45~85%
Air pressure:86~106kPa (860~1060 mbar)
Should any doubt arise in judgment. tests shall be conducted at the following conditions.
Ambient temperature:20±2℃
Relative humidity:60~70%
Air pressure:86~106kPa (860~1060 mbar)
3.2Appearance construction and dimensions
3.2.1 Appearance Switch shall have good finishing, and no rust crack or plating failures.
3.2.2Construction and dimensions Refer to individual product drawing.
Trip 2.5±0.5mm
Contact pressure ≥0.4N
The deviation in contact center no large than a quarter of contact diameter
Gap≥2.5mm
Drive type Press button kind, self-lock singe reset mechanical system
3.3. Electrical specifications
NO. |
Items |
Test conditions |
Criteria |
3.3.1 |
Contact resistance |
MEASURED AT 1 KHz SMALL CURRENT(100 mA OR LESS)
|
30mΩ MAX 30毫欧以下。 |
3.3.2 |
Insulation resistance |
APPLY A VOLTAGE OF 500V DC SHALL BE APPLIED FOR 1 MIN AFTER WHICH MEASUREMENT BE MADE: (1) BETWEEN TERMINAL. (2) BETWEEN INDIVIDUAL TERMINAL AND FRAME.
|
100MΩ MIN
|
3.3.3 |
Voltage proof |
AC 500V rms(50~60Hz) FOR 1 MIN TRIP CURRENT: 0.5 mA 1)BETWEEN TERMINAL. 2)BETWEEN INDIVIDUAL TERMINAL AND FRAME.
|
WITHOUT DAMAGE TO PARTS ARCING OR BREAKDOWN ETC.
|
3.4 Mechanical characteristic
Item |
Description |
Test Conditions |
Standards |
1 |
Terminal strength |
A STATIC LOAD OF 300 gf SHALL BE APPLIED TO THE TERMINAL FOR 15 SEC. IN ANY DIRECTION.
|
THERE SHALL BE NO DAMAGE TO THE TERMINAL SUCH AS CRACKS, LOOSENESS OR PLAY.ELECTRICAL AND MECHANICALCHARACTERISTICS SHALL BE SATISFIED. |
2 |
DISPLACEMENT OF ACTUATOR (KNOB)
|
A STATIC LOAD OF 10N(1Kgf)SHALL BE APPLIED TO THE TOP OF THE ACTUATOR(KNOB) AND THEN DISPLACEMENT SHALL BE MEASURED TO THE DIRECTION OF THE ARROW. |
THE LEVER SHALL HAVE NO ANFUNCTION IS NORMALLY.
|
3 |
LIFE TEST
|
WITHOUT LOAD: AN ACTUATOR SHALL BE SUBJECT TO 10,000 CYCLES AT A SPEED OF 15~18 CYCLES FOR 1 MIN.
|
1)CONTACT RESISTANCE 100 mΩ MAX 2)INSULATION RESISTANCE 50MΩ MIN. 3)WITHSTAND VOLTAGE AC 500V, 1 MINUTE. (4)OPERATING FORCE ±30% INITIAL VALUE. (5)WITHOUT DAMAGE TO PARTS ARCING OR BREAKDOWN ETC.
|
3.5. Durability
NO. |
Item |
Test conditions |
Criteria |
3.5.1 |
HUMIDITY
|
THE JACK SHALL BE STORED AT A TEMPERATURE OF 40±2 °C AND A HUMIDITY OF 90% TO 95% FOR 96 Hr . THEN THE JACK SHALL BE MAINTAINED AT STANDARD ATMOSPHERIC CONDITION FOR 1 Hr FOR OTHER PROCEDURES.
|
|
3.5.2 |
STANDARD ATMOSPHERIC CONDITIONS
|
UNLESS OTHERWISE SPECIFIED. THE STANDARD RANGE OF ATMOSPHERIC CONDITIONS FOR MAKING MEASUREMENTS AND TESTS ARE AS FOLLOWS: (1) AMBIENT TEMPERATURE : 5 °C TO 35 °C (2) RELATIVE HUMIDITY: 45% TO 85% (3) AIR PRESSURE 86Kpa TO 106Kpa
|
|
3.5.3 |
PRACTICAL TEMPERATURE RANG
|
-16 °C ~ +60°C
|
|
3.5.4 |
STORAGE METHOD
|
(1) IF DON'T USE THE PRODUCT IMMEDIATELY,STORE IT AS DELIVERED IN THE FOLLOWING ENVIRONMENT: WITH NEITHER DIRECT SUNSHINE NOR CORROSIVE GAS AND IN NORMAL TEMPERATURES. HOWEVER, IT IS RECOMMENDED THAT YOU SHOULD USE IT AS SOON AS POSSIBLE BEFORE SIX MONTHS PASS. |
|
(2) AFTER BREAK THE SEAL,IT SHOULD PUT THE REMAINING IN A PLASTIC BAG TO SEPARATE IT FROM THE OUTSIDE AND STORE IN THE SAME ENVIRONMENT MENTIONED ABOVE. YOU SHOULD USE IT UP AS SOON AS POSSIBLE. |
|||
(3) DO NOT STACK TOO MANY SWITCHES FOR STRAFE.
|
3.6. Welding Performance
3.6.1 |
Solder ability |
THE TOP OF THE TERMINALS SHALL BE DIPPED 2mm IN THE SOLDER BATH OF 230±5 °C FOR 3±0.5 SECONDS.
|
The area of dip tin should capture the 75% impregnated area |
|||||||||
3.6.2 |
Resistance to soldering heat |
The switch will be inspect under such conditions below Temperature and impregnated time
(2) TMMERSION DEPTH: IMMERSION DEPTH UP TO THE SURFACE OF THE BOARD THICKNESS OF PRINTED WIRING BOARD 1.6 mm.
|
WITHOUT DEFORMATION OF CASE OR EXCESSIVE LOOSENESS OFTERMINALS MECHANICAL AND ELECTRICAL CHARACTERISTICS SHALL BE SATISFIED.
|
|||||||||
3.6.3 |
HEAT TEST
|
THE JACK SHALL BE STORED AT A TEMPERATURE OF 70±2 °C FOR 48 HOURS AND THEN IT SHALL BE SUBJECTED TO THE CONTROLLED RECOVERY CONDITIONS FOR 1 HOUR AFTER WHICH MEASUREMENT SHALL BE MADE.
|
||||||||||
3.6.4 |
COLD TEST
|
THE JACK SHALL BE STORED AT A TEMPERATURE OF -25±3 °C FOR 48 HOURS AND THEN IT SHALL BE SUBJECTED TO THE CONTROLLED RECOVERY CONDITIONS FOR 1 HOUR AFTER WHICH MEASUREMENT SHALL BE MADE.
|
4. DRAWING & DIMENSION:
5. CIRCUIT DIAGRAM: