R-SWH10C5W-LBR5-115NC paddle switch 4 pins ON-OFF DPDT red light momentary rocker switch used for elevator
Series:R
Quick Detail:
Type: R-SWH10C5W-LBR5-115NC
Construction category: D类
Operation method: Rocker Action
Configuration: Double-Pole Single-Through (DPST)
Terminal form: 250 quick-connect Terminal
Mounting: Snap-In
Protection: IP40
- Remarks
- Applications
- Technical parameters
Remarks
SAFETY APPROVAL & RATING:
1. 20A 125VAC; 3/4HP 250VAC(UL)
2. 16A 125/250VAC, 1/4HP(UL, CSA)
3. 16(4) A 250V~T125/55 (VDE ENEC)
4. 10(2) A, 250V~ 5E4 T125/55 (VDE ENEC)
5. 16(8) A, 250V~T125/55 (VDE/ENEC)
PARTS LIST:
ITEM |
NAME |
MATERIAL |
1 |
Base |
Plastic |
2 |
Button |
Plastic |
3 |
Lamp holder |
Nylon 66 94V-0 |
4 |
Contact |
Silver zinc alloy |
5 |
Contact |
Silver zinc alloy |
6 |
Spring |
Jean steel wire |
7 |
resistance |
resistance |
8 |
Light |
Neon lamp-Red |
9 |
Terminal |
Copper tin plating |
10 |
Terminal |
Copper tin plating |
11 |
Moving piece |
Copper plating silver |
12 |
White oil |
White oil |
13 |
Ink |
Ink |
Returned plastic should not exceed 20%.
Applications
Home / Household Appliances
Electric kettle, Robot cleaner, Dust catcher, Vacuum cleaner, Coffee maker, Running machine etc.
Electronic Equipment
Toys, Power tools, Car control panel etc.
Medical Equipment
Communication Equipment
Automation Equipment
Automotive Electronics
Instrumentation
Technical parameters
1. DETAIL SPECIFICATIONS:
Type: R-SWH10C5W-LBR5-115NC
Construction category: D类
Operation method: Rocker Action
Configuration: Double-Pole Single-Through (DPST)
Terminal form: 250 quick-connect Terminal
Mounting: Snap-In
Protection: IP40
1.1 OPERATING CHARACTERISTICS
R series switch operation force |
|||||
Single-Pole |
Double-Pole |
||||
|
Function |
Operation force |
|
Function |
Operation force |
1 |
ON-OFF |
400±200 gram |
1 |
ON-OFF |
600±200 gram |
2 |
ON-ON |
400±200 gram |
2 |
ON-ON |
600±200 gram |
3 |
ON-OFF-ON |
400±200 gram |
3 |
ON-OFF-ON |
600±200 gram |
4 |
(ON)-OFF |
1000±200 gram |
4 |
(ON)-OFF |
1000±200 gram |
5 |
(ON)-ON |
1000±200 gram |
5 |
(ON)-ON |
1000±200 gram |
6 |
(ON)-OFF-(ON) |
1100±300 gram |
6 |
(ON)-OFF-(ON) |
1100±300 gram |
7 |
(ON)-OFF-ON |
(900±300)-200±100 gram |
7 |
(ON)-OFF-ON |
(1300±300)-700±200 gram |
( ):Momentary |
1.2 GENERAL CHARACTERISTICS
1.2.1Application This specification is applied to R Rocker Switch used for electronic equipment.
1.2.2 Operating temperature range 0℃ to 125℃
1.2.3 Test conditions Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows
Ambient temperature: 15~35℃
Relative humidity: 45~85%
Air pressure: 86~106kPa (860~1060 mbar)
Should any doubt arise in judgment. tests shall be conducted at the following conditions.
Ambient temperature: 20±2℃
Relative humidity: 60~70%
Air pressure: 86~106kPa (860~1060 mbar)
1.3 Appearance construction and dimensions
1.3.1 Appearance Switch shall have good finishing, and no rust crack or plating failures.
1.3.2 Construction and dimensions Refer to individual product drawing.
1.4 Electrical specifications
NO. |
Items |
Test conditions |
Criteria |
3.4.1 |
Contact resistance |
Measure by micro-ohm meter at DC. 5V 1A Applied position: Between terminal and terminal |
20mΩ MAX |
3.4.2 |
Insulation resistance |
Measure with DC. 500V applied between terminals of open contacts and betweenterminals of opposite polarity. |
100MΩ MIN |
3.4.3 |
Voltage proof |
A switch shall withstand for 1 minute without breakdown or arc in a potential applied between terminals of open contacts and between terminals of opposite polarity, and between terminals and frame as following: 1000 volts for a switch rated 250VAC or less. (UL) 1500 volts for a switch rated 250VAC or less. (IEC) |
No dielectric breakdown shall occur |
1.5 TEMPERATURE TEST
The test should be taken after load test with its rated current and voltage, and measured by the following standards. 3.5.1. The temperature rise after the load test shall not be more than 30℃. (UL) 3.5.2. The temperature rising shall not be more than 55℃. (IEC) |
1.6 PULL TEST
A static force of 5 pound (2.27kg) being applied in one direction on the tip of the terminal for 1 minute. The terminal may be deformed, but shall not sustain any trouble as deviation and breaking of terminal and breaking of insulation material. |
1.7 TERMINAL STRENGTH
The force required to insert and withdraw the tab and connector of a quick-connect terminal shall comply with the values as follows: 1.7.1 First insertion: 18 pounds, max. Individual. 1.7.2 First withdrawal: 20 pounds, max. Individual. 3 pounds, min individual. 1.7.3 Sixth withdrawal: 2 pounds, min. individual. |
1.8. WELDING CHARACTERISTICS
1.8.1 |
S.M.T. dipping: |
The temperature of soldering should be 260±5℃within 5±1 seconds of dipping duration, and more than 75% of the terminal shall be covered by solder. |
After the soldering, the switch shall not have any deformations or fail to function |
1.8.2 |
Handwork soldering |
The temperature of soldering should be 350±5℃when applied with a 60W iron head, and should abide by the following rules: 1) The soldering iron shall not be pressed to terminal when soldering, but only slightly touch the surface of the terminal 2) Soldering time should be controlled within 3 seconds, at most not exceeding 5 seconds. 3) After the soldering, the switch shall not have any deformations or fail to function. |
No dielectric breakdown shall occur |
1.9. ENDURANCE
NO. |
Items |
Test conditions |
Criteria |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1.9.1 |
Mechanical life test |
The switch applied without electric load, should operate at least 50,000 times, without mechanical failure. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1.9.2 |
Load test |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1.9.3 |
Endurance test |
|
1.10 Environment resistance
NO. |
Item |
Test conditions |
Criteria |
1.10.1 |
Cold |
Put the switch at -40±2℃for 96 hours and then take it out one hour measuring it at normal temperature and humidity surrounding within one hour after clean off water vapor. |
Contact resistance: Lower 20m. Insulation resistance: Over 100M. Dielectric voltages withstand: The same as Point No. 3.4.3 |
1.10.2 |
Dry heat |
Put the switch at 85±2℃for 96 hours and then take it out one hour, measuring it at normal temperature and humidity surrounding within one hour after clean off water vapor. |
|
1.10.3 |
Humidity endurance |
Put the switch at 40±2℃relative humidity 90 to 95% for 96 hours and then take it out one hour, measuring it at normal temperature and humidity surrounding within one hour after clean off water vapor. |
2. DRAWING & DIMENSION:
3. CIRCUIT DIAGRAM:
4. PACKING:
4.1 |
Packing material: |
Plastic bag / |
4.2 |
Packing number: |
200 pieces per bag |
4.3 |
Weight: |
Gross Weight: 8 kg Net Weight: 7 kg |