SW50-DTS-05L 5POSITION SMD Switch with Extended actuator
Series:SW50-DTS-05L
Quick Detail:
Type: SW50-DTS-05L
Operation method: DIP Switch
Comply with: ■IP40 □IP65 □IP67 □IP68
Rating: 50V DC 0.1A
- Remarks
- Applications
- Technical parameters
Remarks
PARTS LIST:
NO |
NAME |
QTY |
MATERIAL |
1 |
Cover |
1 |
PPS |
2 |
Contact |
* |
Copper |
3 |
Actuator |
* |
PA48 |
4 |
Terminal |
* |
Brass |
705 |
Base |
1 |
PPS |
Applications
1.Digital Products: digital camera, digital video and so on;
2.Remote Control: the remote control of automobile domestic security products;
3.Communication Products: mobile phone, vehicle-mounted phone, telephone set, building equipment, PDA and so on;
4.Homehole appliances: TV set, microwave oven, electric rice cooker, electric fans ,refrigerator,washer;air-conditioning and so on;
5.Security Products: visual interphone, monitor and so on;
6.Toys: electric toys and so on;
7.Computer Products: PC camera and so on;
8.Exercises Machines: treadmills, massage armchair and so on;
9.Medical Device: sphygmomanometer, thermometer, hospital call system and so on;
10.Others: laser pen ,Pointer,Wireless mouse remote control pen,Laser projection pen,page turner,electronic pen;MousePen;overhead projector and so on;
11.Operating switches in all types of electronic equipment such as audio devices, office devices, communication devices, measuring instruments, TVs, video recorders,automotive sets, etc.
12.Household appliances, electric force, telecommunications, machine tool, vessel, textile, printing, Mining machine, Music Instrument, etc.
Technical parameters
1.1 GENERAL CHARACTERISTIC:
1.1.1 Application This specification is applied to DIP Switch used for electronic equipment.
1.1.2 Operating temperature range -30℃ + 85℃
1.1.3 Test conditions
Unless other :specified. The atmospheric conditions for making measurements and tests are as follows:
Ambient temperature: 5~35℃
Relative humidity: 45~85%
Air pressure: 86~106kPa (860~1060 mbar)
Should any doubt arise in judgment. tests shall be conducted at the following conditions.
Ambient temperature: 20±2℃
Relative humidity: 60~70%
Air pressure: 86~106kPa (860~1060 mbar)
1.2 Appearance construction and dimension:
1.2.1 Appearance
Switch shall have good finishing, and no rust crack or plating failures.
1.2.2 Construction and dimensions
Refer to individual product drawing.
1.3. ELECTRICAL SPECIFICATION
ITEM |
DESCRIPTION |
TEST CONDITIONS |
REQUIREMENTS |
1.3.1 |
Contact Resistance |
1) To be measured between the two terminals associated with each switch pole. 2) Measurements shall be made with a 1kHz shall current contact resistance meter. |
50mΩ MAX. (initial) |
1.3.2 |
Insulation Resistance |
500V DC, 1 minute ± 5 sec. |
100MΩ MIN |
1.3.3 |
Dielectric withstand-ing Voltage |
500V AC (50Hz or 60 Hz) shall be applied between all the adjacent terminals and between the terminal and the frame for 1 minute. |
There shall be no breakdown or flashover. |
1.3.4 |
Capacitance |
1MHz±10kHz |
5 pF Max |
1.3.5 |
Operation Force |
Applied in the direction of operation. ON→OFF OFF→ON
|
350gf Max |
1.4. ENVIRONMENT RESISTANCE:
ITEM |
DESCRIPTION |
TEST CONDITIONS |
REQUIREMENTS |
1.4.1 |
Resistance Low Temperature |
Following the test set forth below the sample shall be left in normal temperature and humidity conditions for an hour before measurements are made : 1)Temperature : -30±3℃ 2)Time: 96 hours |
1)As shown in item 1.3.1-1.3.5 2)Contact Resistance: 50mΩ max. |
1.4.2 |
Resistance High Temperature |
Following the test set forth below the sample shall be left in normal temperature and humidity conditions for an hour before measurements are made : 1) Temperature : 85±2℃ 2) Time: 96 hours |
|
1.4.4 |
Resistance Humidity |
Following the test set forth below the sample shall be left in normal temperature and humidity conditions for an hour before measurements are made : 1) Temperature : 40℃±2℃ 2) Relative Humidity :90~95% 3) Time: 96 hours |
1)As shown in item 1.3 2)Contact Resistance: 50mΩ max. 3)Insulation Resistance: 100MΩ MIN |
1.5. SOLDERING CONDITIONS:
1.5.1 |
Solder ability |
Switch test under such conditions and inspect after. 1)Variable temperature range :235±5℃; 2)Dip time:3±0.5s; |
The area of dip tin should capture the 95% impregnated area |
||||||
1.5.2 |
Resistance to soldering heat |
The switch will be inspect under such conditions below Temperature and impregnated time
|
All of the appearance, motor functions, electrical properties are no abnormal. |
1.6. DURABILITY:
1.6.1 |
Operation Life |
Measurements shall be made following the test set forth below: 1) 25mA, 24VDC resistive load 2) Rate of Operation: 15~20 cycles/ minute 3) Cycle of Operation: 1000 cycles. |
1)As show in item 1.3 2)Contact Resistance: 100mΩmax. (final-after test) |
1.6.2 |
Stop Strength |
A static load of 1kgf is applied in the operating direction and pulling direction operated for a period of 15 seconds. |
There shall be no sign of damage mechanically.
|
1.6.3 |
Vibration |
Shall be vibrated in accordance with Method 201A of MIL-STD-202F 1) Frequency: 10-55-10 Hz 1 min/cycle. 2) Direction: 3 vertical directions including the direction of operation. 3) Test Time: 2 hours each direction.
|
As shown in item 1.3.1-1.3.5 |
2. DRAWING & DIMENSION:
3. PACKING:
3.1 |
Packing material: |
Tape |
3.2 |
Packing number: |
1000 pieces per tape |
3.3 |
Weight: |