Remarks
-
SAFETY APPROVAL & RATING:
Approved Rating
Mark
Reference No.
UL&CUL
VDE
3A 250VAC
CQC
CQC13003091205
NEMKO
SEMKO
FIMKO
DEMKO
CE
TUV
ENEC
EK
CB
PARTS LIST:
ITEM
NAME
MATERIAL
1
BUTTON
PLASTIC
2
BASE
PLASTIC
3
SPRING
SWC
4
SLEEVE
IRON
5
MOVING PIECE
BRASS ALLOY, TIN AND ANTIMORY PLATED
6
CONTACT
Silver-Cadmium Oxide alloy
7
TERMINAL
BRASS ALLOY, TIN AND ANTIMORY PLATED
Returned plastic should not exceed 20%.
Applications
Home / Household Appliances
Electric kettle, Robot cleaner, Dust catcher, Vacuum cleaner, Coffee maker, Running machine etc.
Electronic Equipment
Toys, Power tools, Car control panel etc.
Medical Equipment
Communication Equipment
Automation Equipment
Automotive Electronics
Instrumentation
Technical parameters
DETAIL SPECIFICATIONS:
Type:SY601B-SW101011BB
Construction category: D
Operation method: Rocker Action
Configuration: Single-Pole Single-Through (SPST)
Terminal form: #250 quick-connect Terminal
Mounting: Snap-In
Protection: IP40
1.1OPERATING CHARACTERISTICS
Characteristics |
Units |
Standards |
Note |
Actuating Force |
N |
4±1.5 Max |
Original 4±1.5 |
Contact Force |
N |
0.4 Min |
Original 0.4 Min |
Electrical Clearance |
mm |
3 Min |
Original 3 Min |
Note:
Actuating Force:The force required to move the actuator from the free to the operation position
1.2 GENERAL CHARACTERISTICS
1.2.1Application This specification is applied to SY601H Rocker Switch used for electronic equipment.
1.2.2Operating temperature range 0℃to+125℃
1.2.3 Test conditions Unless otherwise specified. The atmospheric conditions for making measurements and tests are as follows
Ambient temperature: 5~35℃
Relative humidity: ≤85℅ RH
Air pressure: 86~106kPa (860~1060 mbar)
Should any doubt arise in judgment. tests shall be conducted at the following conditions.
Ambient temperature: 20±2℃
Relative humidity: 60~70%
Air pressure: 86~106kPa (860~1060 mbar)
1.3 Appearance construction and dimensions
1.3.1 Appearance Switch shall have good finishing, and no rust crack or plating failures.
1.3.2 Construction and dimensions Refer to individual product drawing.
1.4. Electrical specifications
NO. |
Items |
Test conditions |
Criteria |
1.4.1 |
Contact resistance |
Shall be measured at 1A 250VAC by voltage drop method after some operations without load. Applied position: Between terminal and terminal |
50mΩ MAX |
1.4.2 |
Insulation resistance |
Test voltage:500VDC, measured after 1 min ±5s Applied position: 1)Between terminal and terminal 2)Between terminal and ground |
100MΩ MIN |
1.4.3 |
Voltage proof |
Following test voltages shall be applied for 1 min. (Cut-off current:0.5mA) 1)Between terminal and terminal :1500VAC/min (50~60Hz) |
No dielectric breakdown shall occur |
1.5. ENVIRONMENT RESISTANCE
NO. |
Item |
Test conditions |
Criteria |
1.5.1 |
Cold |
After testing at -20±2℃ for 96 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. water drops shall be removed. |
Contact resistance (item 4.1): 100mΩ MAX Insulation resistance (item 4.2): 50MΩ MIN Voltage proof: (item 4.3) No dielectric breakdown shall occur. Operating characteristic (item 5.1): Operating characteristic variety Within ±10% of specified value . No abnormalities shall be recognized in appearance and construction. |
1.5.2 |
Dry heat |
After testing at 85±2℃ for 96 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. |
|
1.5.3 |
Damp heat |
After testing at 40±2℃ and 90-95%RH for 96 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. water drops shall be removed. |
|
1.5.4 |
Change of temperature |
After 20 cycles of following conditions the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. water drops shall be removed. |
|
1.5.5 |
Salt mist |
Switch shall be checked after following lest. 1) Temperature: 35±2℃ 2) Salt solution: 5±1% (solids by mass) 3) Duration: 24±1h After test, salt deposit shall be removed in running water |
No remarkable corrosion shall be recognized in metal part |
1.6. WELDING CHARACTERISTICS
1.6.1 |
Solder ability |
Switch test under such conditions and inspect after. 1)Variable temperature range :235±5℃; 2)Dip time:3±0.5s; |
The area of dip tin should capture the 95% impregnated area |
|||||||||
1.6.2 |
Resistance to soldering heat |
The switch will be inspect under such conditions below Temperature and impregnated time
|
All of the appearance, motor functions, electrical properties are no abnormal. |
1.7. ENDURANCE
NO. |
Item |
Test condition |
Criteria |
||||||||||||||||||
1.7.1 |
Endurance (According to UL61058) |
3A 250VAC Switch shall be operated according to following sequence (Test1~Test2)
Voltage proof(Cut-off current:0.5mA) 1GPA 125/250VAC ; Switch shall be operated 10,000 cycles at 15-20 cycles/min. Test voltages shall be applied for 1 min |
Insulation resistance (item 4.2): 30MΩ MIN Voltage proof: Terminal and ground: 1000VAC No dielectric breakdown shall occur. Operating characteristic (item 5.1): Operating characteristic variety Within ±20% of specified value . 6000 cycles temperature rise:30℃ MAX; 10,000 cycles temperature rise:55℃ MAX;
No abnormalities shall be recognized in appearance and construction |
||||||||||||||||||
1.7.2 |
Endurance (According to EN61058-1 /IEC61058-1) |
3A 250VAC Switch shall be operated 10.000 cycles at 15~20 cycles/min Voltage proof(Cut-off current:0.5mA) Test voltages shall be applied for 1 min. |
Insulation resistance (item 4.2): 50MΩ MIN Voltage proof: Terminal and terminal:750VAC Terminal and ground:1500VAC No dielectric breakdown shall occur. Operating characteristic (item 5.1): Operating characteristic variety Within ±20% of specified value . Temperature rise:55℃ MAX No abnormalities shall be recognized in appearance and construction |
2.DRAWING & DIMENSION:
3.CIRCUIT DIAGRAM:
4. PACKING:
4.1 |
Packing material: |
Plastic bag / |
4.2 |
Packing number: |
200 pieces per bag 1 shipping carton 6000 pieces |
4.3 |
Weight: |
Gross Weight: 26 kg Net Weight: 24.5 kg |
4.4 |
Size: |
57*27*32CM /0.049248CBM |