TS10W-236C 10*10mm waterproof tact switch height is 23.6mm push button switch 4 pins DIP switch momentary tactile switch
Series:TS10W
Quick Detail:
Type: TS10W-236C series
Operation method: Tact Action
Configuration: Tactile feedback
Terminal form: PCB type
SMT type:(□BRAID ■NO BRAID)
Mounting: Jack socket
Protection: comply with □IP40 □IP65 ■IP67 □IP68
- Remarks
- Applications
- Technical parameters
Remarks
-
4. PARTS LIST:
No.
Name
Material
1
1
Push an axis
PC
2
1
Cover
PBT
3
1
Sealed mat
0.45 The silicone
4
1
Waterproof mat
Waterproof adhesive
5
1
Cushion
PA66
6
1
Dome
Single side stainless steel plated with silver
7
1
Base
PA FR50
8
1
Inlays
H65 Cooper/silver plated
Returned plastic should not exceed 20%.
Applications
1.Audio Products:MP3,MP4,DVD. Audio;
2.Digital Products: digital camera, digital video and so on;
3.Remote Control: the remote control of automobile domestic security products;
4.Communication Products: mobile phone, vehicle-mounted phone, telephone set, building equipment, PDA and so on;
5.Homehole appliances: TV set, microwave oven, electric rice cooker, electric fans ,refrigerator,washer;air-conditioning and so on;
6.Security Products: visual interphone, monitor and so on;
7.Toys: electric toys and so on;
8.Computer Products: PC camera and so on;
9.Exercises Machines: treadmills, massage armchair and so on;
10.Medical Device: sphygmomanometer, thermometer, hospital call system and so on;
11.Others: laser pen ,Pointer,Wireless mouse remote control pen,Laser projection pen,page turner,electronic pen;MousePen;overhead projector and so on;
12.Operating switches in all types of electronic equipment such as audio devices, office devices, communication devices, measuring instruments, TVs, video recorders,automotive sets, etc.
13.Household appliances, electric force, telecommunications, machine tool, vessel, textile, printing, Mining machine, Music Instrument, etc.
Technical parameters
2.1 General
2.1.1 Application This specification is applied to TACT Switch used for electronic equipment.
2.1.2 Operating temperature range -40℃ ~ +85℃
2.1.3 Storage temperature -40℃ ~ +85℃
2.1.4 Test conditions
Ambient temperature 5~35℃
Relative humidity 45~85%
Air pressure 86~106kPa (860~1060 mbar)
Should any doubt arise in judgment. tests shall be conducted at the following conditions.
Ambient temperature: 20±2℃
Relative humidity 60~70%
Air pressure 86~106kPa (860~1060 mbar)
2.2 Appearance construction and dimensions
2.2.1 Appearance Switch shall have good finishing, and no rust crack or plating failures.
2.2.2 Construction and dimensions Refer to individual product drawing.
2.3. ELECTRICAL SPECIFICATION
NO. |
Items |
Test conditions |
Criteria |
2.3.1 |
Contact resistance |
Shall be measured at 5V 1mA by voltage drop method after 1.5~2 times operations without load. Applied position: Between terminal and terminal |
50mΩ MAX |
2.3.2 |
Insulation resistance |
Test voltage:100V, measured after 1 min ±5s Applied position: 1)Between terminal and terminal 2)Between terminal and ground |
100MΩ MIN |
2.3.3 |
Voltage proof |
Following test voltages shall be applied for 1 min. (Cut-off current:0.5mA) Between terminal and terminal :250VAC (50~60Hz) |
No dielectric breakdown shall occur |
2.3.4 |
Contact bounce |
Lightly striking the center of the stem at a rate encountered in normal use (3 to 4 times per second), and bounce shall be tested at “ON” and “OFF” |
ON-3msec.max OFF-8msec.max |
2.4. ENVIRONMENT RESISTANCE
NO. |
Items |
Test conditions |
Criteria |
|||||||||||
2.4.1 |
Cold |
After testing at -40±2℃ for 1000 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1h water drops shall be removed. |
Contact resistance: 200mΩ MAX Insulation resistance: 50MΩ MIN Voltage proof: No dielectric breakdown shall occur. |
|||||||||||
2.4.2 |
Dry heat |
After testing at 85±2℃ for 1000 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1h |
||||||||||||
2.4.3 |
Damp heat |
After testing at 60±2℃ and 90-95%RH for 1000 h, the switch shall be allowed to stand under normal room temperature and humidity condition for 1h, and then measurement shall be made within 1 h. water drops shall be removed. |
||||||||||||
2.4.4 |
Change of temperature |
Following 5 cycles of the temperature cycling test set forth below the sample shall be left in normal temperature and humidity conditions for one hour before measurements are made. During this test, water drops shall be removed.
|
||||||||||||
2.4.5 |
Thermal Shock |
Temperature 40± 2 ℃ ~ 85 ± 2 ℃ (85 ± 2 ℃ for 1 hour, and 40 ± 2 ℃ for 1 hour, 2 hours) take out after 200 cycles. |
Operating characteristic: Operating characteristic variety Within ±10% of specified value . |
|||||||||||
2.4.6 |
Waterproofing |
The switch shall be checked after following test: 1) Temperature :60±2℃ 2) Time: 240 hour. |
||||||||||||
2.4.7 |
Salt water Resistance |
Puts switch temperature 35 ±2 ℃, 5% concentration 1 injection pressure placed 96 hours, wash by water and salt, placed in the normal temperature environment for 1 hour. |
||||||||||||
2.4.8 |
Drug Resistance 1 |
Put switch in weak alkaline household synthetic detergent 0.28% after 96 hours in the 10cm depth. |
||||||||||||
2.4.9 |
Drug Resistance 2 |
Put switch at department of chlorine bleach source liquid water depth of 10 cm 1 hour, washed by water, 1 hour and then placed in the normal temperature environment. |
||||||||||||
2.4.10 |
SO2 Resistance |
To put switch at 40±2 ℃, 75% H, S02 (10 PPM) take out after 240 hours, put in the room temperature environment for 1 hour. |
||||||||||||
2.4.11 |
H2S Resistance |
To put switch at 40±2 ℃, 75% H, H2S (1 PPM) take out after 240 hours, put in the room temperature environment for 1 hour. |
||||||||||||
2.4.12 |
Condensation experiment |
Temperature - 5 ± 2 ℃ ~ 65 ± 2 ℃ for 8 hours (a period), humidity 98% H 125 cycles (1000 hours) temperature - 5 ± 2 ℃ ~ 65 ± 2 ℃ (5 ± 2 ℃ for 2 hours; 65 +±2 ℃ for 6 hours, 8 hours), relative humidity 98% H environment, take out after 125 cycles. |
No abnormalities shall be recognized in appearance and construction. |
|||||||||||
2.4.13 |
Welding heat resistance |
Dip switch pin soldering root depth to pin 2-2.5 mm, soldering temperature 255 ℃, dipping time 5 s (available t1.5 mm shutter) , put 1-2 hours at room temperature. |
2.5. WELDING PERFORMANCE
2.5.1 |
Solder ability |
Switch test under such conditions and inspect after. 1)Variable temperature range :250±5℃; 2)Dip time:4±0.5s; |
The area of dip tin should capture the 90% impregnated area |
|||||||||
2.5.2 |
Resistance to soldering heat |
The switch will be inspect under such conditions below Temperature and impregnated time
|
All of the appearance, motor functions, electrical properties are no abnormal. |
2.6. DURABILITY
2.6.1 |
Operation life |
Measurement shall be made following the test set forth below: DC 24V, 30 mA resistance load; Rate of operation:60 times/min; Operating Force:1.5 times; Average fault-free life: 100,000 cycles |
Contact resistance: ≤500mΩ Contact bounce: ≤10ms Operating Force: initial value±30% |
2.6.2 |
Vibration Resistance |
Measurements shall be made following the test set forth below: 1) Vibration frequency range: 10~55~10Hz; 2) Amplitude: 1.5mm; 3) Direction of vibration: three mutually perpendicular direction including the direction of stem travel 4) Duration: Each 2hours. |
|
2.6.3 |
Operation Force |
The switch is placed perpendicular to the direction of the operation, gradually force in key top center of switch, measure maximum intensity when it conducted required |
260±70g |
2.6.4 |
Over Travel |
Switch at the vertical operating orientation placement, with a force equal to 2 times according to the static load applied on the switch button the top center, measure the top moving distance |
0.30±0.10mm |
2.6.5 |
Resilience |
The switch is placed perpendicular to the direction of the operation, the switch key top center fell to a full stroke, the converted measurement from the top of the intensity of free position. |
50gf.min. |
2.6.6 |
Stop strength |
The switch is placed perpendicular to the direction of the operation, the static load applied 29.4N from the operation direction keys to continue 1min. |
no mechanism and electricity damage |
2.6.7 |
handle pull out strength |
The switch is placed perpendicular to the direction of the operation, applying tension on the keys from the opposite direction of operation, measure the maximum tension when the key is pulled out. |
29.4N.min. |
3. DRAWING & DIMENSION: